Datasheet
5
TRUE RMS Digital Multimeter (except for MM 4 )
BENNING BENNING BENNING BENNING BENNING BENNING BENNING
MM 4 MM 5-1 MM 5-2 MM 7-1 MM 9 MM 10 MM 11
indicating range 4200 6000 6000 6000 6000 6000 20000
basic accuracy 0.5 % 0.5 % 0.5 % 0.08 % 0.5 % 0.5 % 0.06 %
AC voltage 1 mV – 600 V 0.1 mV - 600 V 0.1 mV - 600 V 10 µV – 1000 V 0.1 mV – 750 V 0.1 mV – 750 V 1 µV – 750 V
DC voltage 1 mV – 600 V 0.1 mV - 600 V 0.1 mV - 600 V 10 µV – 1000 V
0.1 mV – 1000 V 0.1 mV – 1000 V
1 µV – 1000 V
AC current 0.1 A – 300 A – 1 mA - 10 A 10 µA – 10 A 1 mA – 10 A 1 mA – 10 A 1 µA – 10 A
DC current – – 0.1 µA - 10 A 10 µA – 10 A 0.1 µA – 10 A 0.1 µA – 10 A 1 µA – 10 A
resistance 0.1 Ω – 42 MΩ 0.1 Ω - 40 MΩ 0.1 Ω - 40 MΩ 0.1 Ω – 40 MΩ 0.1 Ω – 60 MΩ 0.1 Ω – 60 MΩ 10 mΩ – 2 GΩ
continuity/diode yes/yes yes/yes yes/yes yes/yes yes/yes yes/yes yes/yes
frequency – 0.01 Hz - 50 kHz 0.01 Hz - 50 kHz
0.01 Hz – 100 kHz
1 Hz – 60 MHz 1 Hz – 60 MHz
0.01 Hz – 1 MHz
capacity – 0.01 nF - 1 mF 0.01 nF - 1 mF 1 nF – 10 mF 1 pF – 6 mF 1 pF – 6 mF 1 pF – 40 mF
temperature
–
–
-40 °C up to +400 °C
-40 °C up to +400 °C
– –
-200 °C up to +1.200 °C
volt sensor – yes yes yes – – –
interface – – – – – USB USB
software – – – – – PC–Win MM 10 PC–Win MM 11
memory HOLD HOLD, PEAK HOLD, PEAK HOLD, MAX/MIN HOLD, MAX/MIN HOLD, MAX/MIN
1000 memory locations
Data Log function
– – – – – –
40000 memory locations
measuring method
RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS
measuring category
CAT III 300 V CAT III 600 V CAT III 600 V CAT IV 600 V CAT IV 600 V CAT IV 600 V CAT III 600 V
item no. 044073 044070 044071 044085 044078 044079 044080
TRUE RMS
CAT IV 600 V
TRUE RMS
CAT IV 600 V
MM 10
(MM 9 fig. similar)
MM 7-1
TRUE RMS
MM 5-2
TRUE RMS
MM 5-1
USB
volt sensor
volt sensorvolt sensor
Software PC-Win MM 10/ MM 11
USB
TRUE RMS
MM 11
B E N N I N G W o r l d C l a s s T e s t E q u i p m e n t
All Digital Multimeters
including protective case,
safety leads and battery set.
BENNING MM 5-1, MM 5-2
compact, precise and innovative
• TRUE RMS measuring method
• compact dimensions: 140 x 70 x 33mm (without holster)
• capacity and frequency measurement
• rubber holster with integrated magnetic hanger
•
Volt sensor for non-contact cable break detection (red LED)
•
continuity test by means of red LED and buzzer
•
measuring input for AC/DC current, microampere DC and
temperature as well as LC display with illumination (MM 5-2)
BENNING MM 7-1, MM 10
Digital Multimeter offering highest safety
for industrial applications
• TRUE RMS measuring method for precise measuring re-
sults even for non-sinusoidal signal characteristics
• highest measuring category CAT IV 600 V for highest safety
•
“AutoV” function for automatic AC/DC voltage detection and low
input impedance (LoZ) to suppress reactive voltages (MM 7-1)
• USB interface for measured value transmission (MM 10)
• delivery including software BENNING PC-Win MM 10
BENNING MM 11
TRUE RMS Precision Digital Multimeter
with extraordinary features of performance
•
highest measuring accuracy and a resolution of 20,000 digits
•
data logger / storage function for 40,000 / 1,000 measured
values for recording measuring processes
• sampling rate adjustable from 0.5sec. to 10 min.
• transmitting measuring results via optical USB interface
• delivery including software BENNING PC-Win MM 11
TRUE RMS Digital Multimeter BENNING MM 5-1, MM 5-2, MM 7-1 – MM 11
TRUE RMS measuring method to satisfy highest demands on accuracy