Datasheet
12
BENNING BENNING
IT 115 IT 130
display graphic display
(illuminated)
low-impedance resistance
0.01 Ω – 2000 Ω
insulation resistance 10 kΩ – 1000 MΩ
line impedance 0.01 Ω – 10 kΩ
loop impedance 0.01 Ω – 10 kΩ
short-circuit current 0.01 A – 200 kA
RCD testing
AC/A/F AC/A/F/B/B+
phase sequence yes
voltage, frequency 1 V - 550 V, 0 Hz - 500 Hz
earth resistance yes by means of 044113
current (TRUE RMS)
–
yes by means of 044038
luminous intensity
–
yes by means of 044111
measured value memory
– up to 1800
interfaces
– USB, RS 232
logging software
– yes
item no. 044104
044103
BENNING IT 115, IT 130
TRUE RMS Installation Testers
IT 115
TRUE RMS
CAT IV 600 V
IT 101
Scope of delivery BENNING IT 115
Unambiguous
“PASS”/“FAIL”
indication
BENNING IT 115, BENNING IT 130
TRUE RMS Installation Testers for safety tests on
electrical systems according to IEC 60364
Multifunctional installation testers for complete testing and
efficient troubleshooting of electrical systems
• measurement of the protective conductor line and of the
equipotential bonding line with a testing current of 200 mA
• measurement of the insulation resistance with testing vol -
tages of 50 V, 100 V, 250 V, 500 V and 1000 V
• line impedance and loop impedance measurement (optional
without tripping of the RCD) with calculation of the short-
circuit current (PFC/PSC)
• complete testing of RCDs with nominal fault currents of
10/30/100/300/500/1000 mA
• measurement of contact voltage (without tripping), tripping
time and tripping current (ramp test) of RCDs
• phase-sequence testing in three-phase mains
•
earthing measurement by means of optional earthing kit (044113)
• TRUE RMS voltage measurement of up to 550V
• unambiguous “PASS”/“FAIL” indication by means of
green/red LEDs
Safety Instruments BENNING IT 101, IT
115
and
IT 130
testing of electrical systems in compliance with the standards
BENNING IT 101
Insulation and Resistance Measuring Device
• measurement of the insulating resistance with testing vol -
tages of 50V, 100V, 250V, 500V and 1,000V
• selectable limiting values for ISO measurement, green LED
for “PASS”, red LED for testing voltage/external voltage
• resistance measurement with a testing current of 200 mA
for testing protective conductor connections
• switchable probe tip for triggering the measuring process
• internal memory for 100 measuring values per measuring
function
• TRUE RMS voltage measurement with low-pass filter
• including case, switchable probe tip, silicone measuring
leads, magnetic hook, alligator clips, rubber protective
frame and batteries
BENNING
IT 101
indicating range 4000 digits (illumination)
low-impedance resistance
0.01 Ω – 40 Ω
insulation resistance 1 kΩ – 20 GΩ
resistance 0.01 Ω – 40 kΩ
voltage 0.1 V – 600 V AC/DC TRUE RMS
supplementary function leakage current, polarization index (PI),
dielectric absorption rate (DAR), automatic
discharge function, null balance of the
measuring leads
measured value memory 500 measuring results
measuring category CAT IV 600 V
item no. 044033
BENNING IT 101
Insulation and Resistance Measuring Device
B E N N I N G W o r l d C l a s s T e s t E q u i p m e n t
Scope of delivery BENNING IT 101