Technical data
6.5 Calibrating the device
5191 / 07/2021 en BENNING CM 2-1 39
7 Technical data
Protection class II (double or reinforced insulation)
Contamination level 2
Protection category
(DINVDE0470-1, IEC/ EN60529)
IP30
1stdigit: 3= protection against access to
dangerous parts and protection against solid
impurities (diameter >2.5mm)
2nddigit: 0= no protection against water
Overvoltage category • CATIII 600V to earth
• CATIV 300V to earth
Housing dimensions
(lengthx widthx height)
188mmx 56mmx 28mm
Max. clamp opening 27mm
Weight (batteries included) 0.225kg
Battery life (alkaline batteries) approx. 100h (without background lighting)
Safety measuring lines (item no.: 044145)
Standard IEC/ DINEN61010‑031 (VDE0411‑031)
Overvoltage category
(only applies to the safety measuring lines,
additionally observe the limitations of the
device)
• With attachable protective cap:
– CATIII 1 000V to earth
– CATIV 600V to earth
• Without attachable protective cap:
– CATII 1 000V to earth
Protection class II (double or reinforced insulation)
Contamination level 2
Max. rated current 10A
Length 1.4m
Operation
Max. barometric altitude 2 000m
Operating temperature 0…50°C (do not permanently expose the
device to sunlight)
Max. relative air humidity 80%RH (0…30°C),
75%RH (30…40°C),
45%RH (40…50°C),
non-condensing
Storage
(remove the batteries from the device)
Ambient temperature -20…60°C (do not permanently expose the
device to sunlight)
Max. relative air humidity 80%RH
Table16: Technical data