Instructions

5.9 Voltage indicator
Operation
5191 / 07/2021 enBENNING CM 2-134
5.9.1 Non-contact phase testing
There is a detector located on the top of the device. This detector enables non-contact detection
of alternating fields.
Requirements
Please observe the requirements for measuring [}page26].
Make sure that no voltage is applied to the jacks of the device (“COM” and “+”). Remove
any connected safety measuring lines.
Figure14: Non-contact phase testing
Procedure
1. Set the rotary switch of the device to switch position “Volt Sense/ Lo‑Z Auto‑V”.
2. Press the “ACHFR/ DCAZERO” key to enable the “Voltage indicator” function.
“EF” is shown on the digital display.
3. Place the top of the measuring clamp near the measuring point.
If the symbols “ ” and “EF” are flashing on the digital display, the phase of an earthed
alternating voltage is applied to this measuring area.
Practical tip
Interruptions (cable breaks) in exposed cables– e.g. in cable reels, chains of light, etc.– can
be traced from the feeding point (phase) to the point of interruption.
Functional range: ≥230V