Instructions
Table Of Contents
- Legal notice
- Table of contents
- Table of figures
- List of tables
- 1 Introduction
- 2 Safety
- 3 Scope of delivery
- 4 Device description
- 5 Operation
- 6 Maintenance
- 7 Technical data
- 8 Disposal and environmental protection
- Index
Operation
5.3 Voltage or frequency measurement
5191 / 07/2021 en BENNING CM 2-1 29
Figure11: DC voltage measurement
Procedure
1. Set the rotary switch of the device to switch position “Hz ” or “Volt Sense/ Lo‑Z Auto‑V”.
– “Hz ”: Press the “ACHFR/ DCAZERO” key to set the desired measuring function
(frequency, AC or DC voltage).
– “Volt Sense/ Lo‑Z Auto‑V”: The corresponding measuring function (AC or DC voltage)
and the optimum measuring range are set automatically. The input resistance is
reduced to approx. 3kΩ in order to suppress inductive and capacitive voltages (reactive
voltages).
2. Connect the safety measuring lines to the device [}page27].
3. Bring the safety measuring lines into contact with the measuring points and read the
measured value on the digital display.