BENNING CM 10–PV
quency suppression) in the V AC and A AC functions in order to lter out
high-frequency pulses e. g. at pulsed motor drives. “
HFR
” symbol on the
LC display
K
. The limiting frequency (- 3 dB) of the lter is fg = 800 Hz.
When reaching the limiting frequency fg, the displayed value is lower by
a factor of 0.707 than the actual value without lter. Press the key again
to switch back to normal operating mode.
without HFR (without low-pass filter) with HFR (with low-pass filter)
In order to prevent any danger, always measure a present volt-
age first without low-pass filter (high-frequency suppression) to
detect a dangerous voltage.
INRUSH function (inrush current measurement):
In measuring mode “A AC”, press the HFR key
8
for approx. 2 seconds
to enable the inrush current measurement. At the same time, the digi-
tal display
K
shows the symbol. Press the key again to select a
suitable measuring range. The INRUSH function initiates a measuring
process for 100 milliseconds after a trigger current is applied. The aver-
aged value of this time period is displayed. Press the key
8
for approx.
2 seconds to switch back to the measuring mode.
Trigger current: (> 0.5 A in the 60 A measuring range, > 5 A in the 600 A
measuring range)
engine
off
trigger
point
engine
on
time
5.1.10 The MIN/ MAX key
9
has two functions:
MAX/MIN function:
The MIN/MAX function automatically records and stores the highest and
the lowest measured value. By pressing the key again, the following
values are displayed: “MAX/MIN” displays the current measured value,
“
MAX
” displays the highest value stored and “
MIN
” displays the lowest
value stored. Press the HOLD/ZERO key
5
to pause the MIN/MAX
function. Press the key for approx. 2 seconds to switch back to normal
operating mode.
Voltage indicator function:
Press the key for approx. 2 seconds to enable the voltage indicator func-
tion (VoltSense) for non-contact detection of an alternating eld (see
section 8.10).
5.1.11 The MODE key (blue)
J
has two functions:
Press the MODE key (blue)
J
to select the secondary or third function
of the rotary switch position.
Press the key for approx. 2 seconds to enable or disable the display
illumination.
5.1.12 The BENNING CM 10-PV switches o automatically after approx.
20 minutes (APO, Auto-Power-O). It switches on again if the rotary
switch is switched on from switch position “OFF” or if a key is pressed.
The switch-o time can be set (see section 5.1.13).
5.1.13 The BENNING CM 10-PV oers individual setting possibilities. To
change a setting, press one of the following keys and simultaneously
switch on the BENNING CM 10-PV from the “OFF” position.