Instructions

Technical data
6.1 Cleaning the device
5178 / 03/2021 en BENNING EV 3-2 21
7 Technical data
Input voltage Single-phase: up to 250V
Three-phase: up to 430V
Frequency 50Hz, 60Hz
Max. testing current 40A (10ms) periodic operation
Protection class II (double insulation)
Contamination level 2
Protection category
(DINVDE0470-1, IEC/ EN60529)
IP40
1stdigit: 4 = protection against granular foreign
objects
2nddigit: 0= no protection against water
Overvoltage category CATII 300V to earth
Housing dimensions
(Lengthx widthx height)
200mmx 100mmx 70mm
Length of test cable 0.3m
Weight 0.82kg
BNCsocket
Resistance BNChousing to PE 100kΩ
Resistance BNCcontact to CP 100kΩ
Amplitude error -2%
Operation
Max. barometric altitude 3 000m
Operating temperature 0…40°C
Maximum relative air humidity 95%RH (0…40°C), non-condensing
Storage
Ambient temperature -10…70°C
Maximum relative air humidity 90%RH (-10…40°C)
80%RH (40…60°C)
70%RH (60…70°C)
Table6: Technical data