Instructions
Table Of Contents
4.1 Device structure
Device description
5178 / 03/2021 enBENNING EV 3-214
4 Device description
4.1
Device structure
1
2
3
4
5
6
7
8
Figure1: BENNINGEV3-2 device structure
1 4mm test sockets (N, PE, L1, L2, L3)
for connection to the installation tester
2 BNC socket (output) for testing the CP
signal
3 Test cable 4 Type2 connector (male) for connection
to the charging station (EVSE)
5 Rotary switch “CP-Status/
State” (control pilot)
6 Test socket for connection to the
installation tester
7 Rotary switch “PP-Status/
State” (proximity pilot or plug present)
8 LEDs for phase indication L1, L2 and
L3 (output voltage of the charging
station/ EVSE)
WARNING
Improper use
Danger to life or serious injury is possible due to contact with high electric voltage in case of
incorrect use of the test socket or 4mm test sockets. The device might get damaged. The test
socket and the 4mm test sockets carry mains voltage as soon as one or more LEDs for phase
indication light up.
• Use the test socket, 4mm test sockets and BNCsocket only for the testing purposes
described.
• Do not connect any other load to the test socket.
• The BNCsocket is intended for connection to an oscilloscope.