User manual
27
VDE 0100-compliant demonstration case
1.3 Meaning of the warning and note symbols on the front side
Make sure that the demonstration case is connected only to the mains
YROWDJHFRPSO\LQJZLWKWKHPDLQVYROWDJHVSHFL¿HGXQGHUWKHPDLQVVRFNHW
Otherwise, the demonstration case might be damaged.
Only use sockets with a grounded protective conductor terminal.
There is a protective circuit inside the demonstration case. The demonstration
case cannot be switched on, if it is connected to a socket without a grounded
protective conductor terminal.
The lamp only lights, if the mains plug is connected with proper phase
relation.
Otherwise, the shock-proof must be reversed.
A protective circuit inside the demonstration case switches off the mains
YROWDJHDWWKHLQSXWVWDJHLIWKHH[WHUQDOFRQGXFWRUSKDVHLVQRWFRQQHFWHG
to the correct terminal or if a voltage difference of more than 30 V occurs
between the neutral conductor and the protective conductor.
Use the test socket on the front side for measuring purposes only.
Do not connect any load to the shock-proof socket as otherwise the
GHPRQVWUDWLRQFDVHPLJKWEHGDPDJHGDQGWKHRSHUDWRUPLJKWEHH[SRVHGWR
a dangerous voltage.
'RQRWFRQQHFWDQH[WHUQDOYROWDJHWRWKHVKRFNSURRIVRFNHWDVRWKHUZLVH
a dangerous voltage might be applied to the accessible parts of the
demonstration case.
7KHSURWHFWLYHFRQGXFWRUEXVEDUDQGDOODFFHVVLEOHFRQGXFWLYHSDUWVDUH
not connected to the protective conductor of the mains, but to the neutral
conductor.