BENNING MM 10 PV/ MM 10 1
7.4 Current ranges (AAC/DC) (BENNING MM 10-PV)
Function Measuring range Resolution Measurement accuracy
A AC
6.000 A
10.00 A
0.001 A
0.01 A
± 1.5 % + 5 digits
A DC
6.000 A
10.00 A
0.001 A
0.01 A
± 1.0 % + 5 digits
Max. measuring time:
- 3 minutes at > 5 A (pause > 20 minutes)
- 30 secondes at > 10 A (pause > 10 minutes)
Overload protection: 11 AAC/DC
Frequency range: 45 Hz - 500 Hz (sine)
7.5 Microampere/ milliampere current ranges (µAAC/DC)
(BENNING MM 10-1)
Function Measuring range Resolution Measurement accuracy
µA/mA AC
600.0 µA 0.1 µA ± 1.5 % + 7 digits
6.000 mA
60.00 mA
400.0 mA
0.001 mA
0.01 mA
0.1 mA
± 1.5 % + 5 digits
µA/mA DC
600.0 µA 0.1 µA ± 1.0 % + 7 digits
6.000 mA
60.00 mA
400.0 mA
0.001 mA
0.01 mA
0.1 mA
± 1.0 % + 5 digits
Overload protection: 440 mAAC/DC
Frequency range: 45 Hz - 500 Hz (sine)
7.6 Resistancemeasuringranges(Ω),continuityanddiodetesting
Function Measuring range Resolution Measurement accuracy
Resistance
600.0 Ω 0.1 Ω ± 0.9 % + 7 digits
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
± 0.9 % + 4 digits
40.00 MΩ* 0.01 MΩ ± 1.5 % + 7 digits
Continuity 600.0 Ω 0.1 Ω ± 0.9 % + 7 digits
Diode 1.500 V 0.001 V ± 0.9 % + 4 digits
* Measured values > 10 might cause changing values on the display (max.
± 50 digits).
Overload protection: 1000 VAC/DC
Max. open circuit-voltage: approx. 1.8 V
Continuity test: The built-in buzzer sounds when resistance is less
than 20 Ω to 200 Ω.
Response time: < 100 ms
Acoustic indication: 2.7 kHz
7.7 Capacity ranges (µF)
Conditions: Capacitors discharged and connected in accordance with the polar-
ity stated.
Measuring range Resolution Measurement accuracy
1.000 µF 0.001 µF ± 1.9 % + 7 digits
10.00 µF
100.0 µF
1.000 mF
10.00 mF
0.01 µF
0.1 µF
0.001 mF
0.01 mF
± 1.9 % + 4 digits
Overload protection: 1000 VAC/DC