Unit installation

PLACEMENT
OF THE
UNIT
The
CC500 should
be as
close
to the
chimney
as
possible.
The
CC500
can be
installed
on a
COMBUSTIBLE
floor
using
a
non-combustible
pad
extending
20"
front
and
rear
and 6" on
each side.
The
boiler must
be
properly
LEVELED.
A
1"
(2.5cm) minimum
air
space must
be
maintained under
the
appliance. This
can be
achieved
by
using
four
non-combustible blocks,
a
minimum
of
1"
(2.5cm) thick
x 4"
(10cm) wide
x 8"
(20cm) long,
one to be
placed
under each corner.
INSTALLATION CLEARANCES
(very
important)
Front:
48" One
Side:
6"
Rear:
24"
Other Side:
24"
Smoke Pipe:
18"
FUEL
TANK SUPPLY
The
fuel
supply tank
and
fuel
lines should
be
installed
a
minimum
of
6'
from
the
boiler
and in
accordance with
codes
and
standards having jurisdiction
in
your area.
Use flared
fittings only.
DO
NOT
use
furl
fittings. Protect
the oil
line
from
the
wood
fire
door.
COMBUSTION
AIR
To
achieve satisfactory combustion,
an
adequate supply
of
fresh
air is
required.
In
confined areas,
a
grilled opening
shall
be
provided.
The
minimum total area
of a
grilled opening
is 2
square
feet.
Where
fans
are
used
in the
fuel
storage area, they should
be
installed
so as not to
create negative pressures
in the
room where
the
furnace
is
installed.
VERY
IMPORTANT (READ CAREFULLY)
1.
The
furnace
must
be
installed
by a
qualified technician currently active
in the
heating trade
&
meet
or
exceed
all
local
or
national codes.
2.
DO NOT
TAMPER
WITH
THE
UNIT
OR
CONTROLS
-
CALL
A
QUALIFIED
SERVICE
TECHNICIAN.
3. Use
No.2
furnace
oil
only.
DO NOT USE
GASOLINE, CRANKCASE DRAININGS,
OR ANY OIL
CONTAINING GASOLINE.
Use of
other
fuels
could damage
the
unit
or
present
a
serious
safety
hazard.
4. DO NOT use
furnace
oil in the
solid
fuel
section.
5. DO NOT
BURN GARBAGE
OR
PAPER
IN THE
UNIT
OR
LEAVE COMBUSTIBLE
MATERIALS AROUND
THE
UNIT.
6.
Know
the
location
of the
emergency disconnect switch
for the
unit.
7.
Contact
a
qualified
service technician before remodeling,
for
annual service/maintenance, before
extended periods
of
shutdown
and
before start-up.
8.
DO NOT
stack items
on or
around
the
boiler
-
check
required clearances
on
this page.
9. DO NOT
store
flammable
materials
in the
vicinity
of the
furnace.
10. DO NOT
start this unit
all
components
are
securely
in
place.
11.
DO NOT
start
the
wood
or oil
section until
the
boiler
is
properly
filled
with water (damage will
result voiding
the
warranty).
*Ensure
that
the
water
pressure reducing valve
is
working properly (set
at 12
p.s.i.).
Too
high
a
pressure will
damage
the
boiler (voiding
the
warranty).
*Care
must
be
taken
to
ensure that
the
boiler
will
not be
exposed
to
thermal shock which
can be
caused when
the
system return water temperature
is
more than
40° F
below
the
system supply water temperature.
-2-