Manual
SJ-PM-TFmini-S A00
Benewake (Beijing) Co. Ltd.
Page20
data format to adjust interpretation means.
Cause ②:Due to the physical principles of TFmini-S, the above phenomenon is likely to occur if the
detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent
substance (such as glass and water, etc.)
Troubleshooting: Please avoid use of this product under such circumstance in practice.
Cause ③: The IR-pass filters are blocked.
Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter
(3) No data output
Cause: The product will be strictly inspected before leaving our factory, ensuring that all the shipped
products can work normally. However, some abnormal working matters maybe still occur because of
incidents during the transportation or use.
Troubleshooting: Check whether the power supply is normal; check whether the voltage is within rated
voltage range. If power supply is normal, there will be a red light inside the transmitting lens of TFmini-S.
Check TFmini-S with correct connection sequence and reliable connection.
Check whether the data interpretation is correct. Please carry out the interpretation as per the data format
specified herein.
If the problem persists, please contact our technical support.
(4) There is no data output when LiDAR is connected to PC software.
Cause ①: The PC software only supports the Windows operation system for the time being
Troubleshooting: Use the PC supporting Windows operation system.
Cause ②: TTL - USB board is poorly connected.
Troubleshooting: Check the TTL -USB board with the correct and reliable connection with TFmini-S and
PC.
Cause ③: Driver of serial port is not correctly installed.
Troubleshooting: Plug and unplug USB cable again. Try to reinstall the driver or directly download and
install a driver from the internet.
If the PC software still work abnormally, please contact our technical support.
(5) The accuracy of TFmini-S gets worse at 12m and the data fluctuation becomes larger.