Data Sheet
TF03 Product Manual V0.4
Benewake(Beijing)Co., Ltd.
Page18
3) TF display software connection and reading
Figure 6 The interface of TF display software
As shown in Figure 6, open the TF display program, selectⅠ『Benewake TF03』
and select the serial port for automatic identification (here is Ⅱ『COM9』).
Then, click『CONNECT』to connect to the TF display program.
After connected successfully, continuous output data images will occur in the right
Ⅳ『TIME LINE CHART』area and the Ⅴ『REAL TIME DATA』area below will
display the current test distance (Dist: 125cm), the output frame rate (Effective
Points: 100Hz).
Note: the Dist (Echo) and Strength are unmeaning in here.
4) Another note
If TF03 want to output in Pixhawk mode, check Ⅲ『Pix Mode』 first and then the
data images will be normally output in the Ⅳ『 TIME LINE CHART』 area. After the
Pix Mode is checked, the distance unit will change to m.