Data Sheet
Page 3
SJ-GU-CE30-C-03 A01
1. Product Overview
Feature
➢ Complete Solid-state LiDAR
➢ Area array detecting
➢ Wide horizontal FoV: >120°
➢ Vertical FoV: 9°
➢ Depth and point cloud mode
Table 1 CE30-C specification
Parameter
1
Typical Value
Method
Time of flight
Peak Wave Length
850nm
FoV
2
132*9 degrees
Pixel Resolution
320*24 (device output)
660*24 (SDK output with no loss of FoV
3
)
Frame Rate
20fps
Response time
200ms
Ranging Resolution
1cm
1
Specific parameters may slightly differ due to the test environment and the test method. 20 minutes warm-up time and white board
with the reflectivity of 90% is used below as default. Please refer to section 4.3. Reflectivity of Various Materials.
2
The FoV is open for customization.
3