User manual
MPTP | MPTP commands 94
Check Command format from 4.6.8
The special fields of the command are as follows:
Setting ID
Field Description Range
2400 MPTP SOS Text Defines the text, that is added to the data
field on EMG message when TWIG SOS is
sent from SOS key. Default= SOS
BUTTON
0-15 characters
2401 MPTP MD Text Defines the text, that is added to the data
field on EMG message when TWIG SOS is
sent from Man Down Alert. Default= MAN
DOWN ALERT
0-15 characters
2402 MPTP RF SOS
Text
Defines the text, that is added to the data
field on EMG message when TWIG SOS is
sent from Wrist Alert key. The Date will
have WA-123456567 where the 123456 is
the serial number of the Alarming unit
0-15 characters
2403 MPTP Amber
Alert / Condition
Check text
Defines the text, that is added to the data
field on EMG message when TWIG SOS is
sent from Amber Alert / condition Check.
Default= CONDITION CHECK
0-15 characters
2405 Wireless alert unit Defines the #1 Wireless alarm unit serial
number, that is paired with the unit.
0-15 characters
2406 Wireless alert unit Defines the #2 Wireless alarm unit serial
number, that is paired with the unit.
0-15 characters
2407 Wireless alert unit Defines the #3 Wireless alarm unit serial
number, that is paired with the unit.
0-15 characters
2408 Wireless alert unit Defines the #4 Wireless alarm unit serial
number, that is paired with the unit.
0-15 characters
2409 Wireless alert unit Defines the #5 Wireless alarm unit serial
number, that is paired with the unit.
0-15 characters
2420 Event start delay Define the delay that is used between
events in TWIG SOS. Default 2
0-60 sec
2421 Call timeout Defines the timeout to skip to next event
on SOS list if no answer from B-subscriber
20-300 sec
2422 Full SOS cycles Defines the amount of full TWIG SOS
event cycles to be done. Default 1
1-5
2423 Emergency
number text
Defines the text to be shown when use is
prompted to call network emergency
number. Default 112
1-3 characters