User manual

MPTP | MPTP commands 79
Em. report
recipient
Emergency report phone number for the N
th
record.
valid phone
numbers
Reporting Defines whether an emergency report should
be sent to the Em. report recipient during the
emergency cycle:
0: no
1: yes
0…1
As up to five emergency centers can be defined, the length of one MPTP message may not be enough to
hold the whole persistent setting configuration. Normal rules for concatenating persistent setting
configuring commands described in section 4.6 allow a command to be broken down over several
messages in this case.
4.6.2. Setting 0050: authorized numbers
This command is used setting the phone numbers which are authorized to e.g. ask MTT’s position or
configure it’s settings without question from the user. Requests from authorized numbers are conducted
and answered immediately whereas requests from unauthorized numbers are usually rejected
altogether.
Supported Benefon/TWIG instruments and SW versions: Send Receive
Twig Locator SW 2.06
Command format
Command*
Part number*
Setting ID
Number of authorized
numbers to set
Authorized number 1
Authorized number N
4 1 5 1 4 1 2 1 0…41 1 0…41
?CNF _ 01/01 _ 0050 _ 5 _ +3581234567890 _ +3589876543210
*) cf. section 3.1 for description of these fields.
The special fields of the command are as follows:
Field Description Range
Setting ID Numeric identifier of the setting being
configured. In this case, the ID is 0050.
0000…9999
Number of
authorized
numbers to set
Number of authorized numbers which will be
set by the command. Note! Old numbers will
1…20