User manual
MPTP | MPTP commands 68
Radius
Method
Interval
1…4 1 1 1 1…5
1000 _ 0 _ 15
The special fields of the command are as follows:
Field Description Range
Indication type Defines the type of the indication.
0: Tracking state change caused by
digital input pin
Note that the rest of the fields depend on the
value on this field. At the moment only one
indication type is supported.
0
Time of sending Date and time at which the indication was
sent. Universal Coordinated Time (UTC) is
used.
date and time in
format DD.MM.
YYYY_hh:mm:ss
Pin number Pin number of the digital input pin which
caused the state change.
1…9
Trigger type Trigger type of the tracking in question. For
the anchor tracking the trigger type is 9. Cf.
4.2.1.4 for more information about trigger
types.
0…9
Activity Current activity of the tracking process in
question.
0: Stopped. The tracking process
exists in the device but it is not
actively checking the trigger
conditions until activated by
digital input pin.
1: Active. Active tracking process is
actively checking the trigger
conditions or sending tracking
reports.
0…1
Indication text Textual description of the indication in
question. The text depends on the trigger
type in question and the current activity of
the tracking process. For now only anchor
tracking is supported and for that the
following texts are possible.
0: “Anchor alarm off”
1: “Anchor alarm on”
1…20 chars
Center point Coordinates of centre point of the area, in
WGS-84 format.
cf. field Position in
section 3.1.
Center point
time stamp
Time stamp of the position used as the
center point of the area. Universal
Coordinated Time (UTC) is used.
date and time in
format DD.MM.
YYYY_hh:mm:ss
Radius Radius of tracked area. 1…9999 (m)