User manual
MPTP | MPTP commands 34
relation to the tracked area. Thus, this
parameter is also relevant for Methods 2, 3
and 4.
4.2.1.4.2. Trigger type 1: stopping at report limit
CC → MTT
A type 1 tracking process sends reports at regular intervals until a specified number of reports have been
sent. Such a process can be created and activated by a Control Centre, by sending a complex tracking
request command with trigger type 1.
The tracking process has the following properties:
• Start trigger : None.
The tracking process is started as soon as it is created.
• Interval
The process will send tracking reports at the specified interval until the stop trigger condition is
met. The interval is given in full minutes.
• Stop trigger : Number of reports.
The tracking process is stopped when the specified number of reports have been sent.
A process just like one created with this command can also be created with a simple tracking request; cf.
section 4.2.1.1. If the interval needs to be given in seconds, use the command described in section
4.2.1.2 instead.
Supported Benefon/TWIG instruments and SW versions: Send Receive
Twig Discovery Pro SW CD1P.02.047.00000
•
Twig Discovery Pro (Tracer) SW CD1R.02.054.0000
•
Twig Discovery Pro (Navigation) SW CD1Q.02.054.0000
•
Twig Discovery Pro (Tracer, Navigation) SW CD1S.02.054.0000
•
Twig Protector SW CG1P.01.001.0000
•
Reception
Depending on the authorization of the Control Centre which sent the request, a new tracking process may
be created or the request may be disregarded altogether. Cf. section 2.1.3 for more information.