User`s manual

CONFIGURATING LOCATOR
32
1
= Launches man down alert when vertical
condition is met.
2
= Launches alert if detected movement is
less than defined in configuration settings.
37 for a longer period than defined in con-
figuration settings 40 (no-alarm duration
and pre-alarm duration combined).
Config 40: Man down timers
This setting defines timers to be used with
man down alert. Define the desired values for
each timer, separated by comma (e.g.
3,20000,10). Note that the maximum amount
of characters in the field is 16.
No alarm duration
:
When an alarm-triggering
orientation (vertical/horizontal by defini-
tion) has been detected, device enters to a
no alarm period during which it waits for
normal orientation to be restored, before
actually triggering the alarm. This is useful
to prevent unnecessary alarms e.g. in case
the user has fallen down but is able to get
up quickly. No alarm period can be set to
3
-
65535
seconds.
Pre-alarm duration
: When an alarm-triggering
orientation has been detected, and the no
alarm period has passed, device enters into
pre-alarm period. During this state the user
is alarmed by vibration, activating in 1-2
second periods. When pre-alarm period is
over, and normal orientation is not restored,
man down alert is launched. Pre-alarm
period can be set to
3
-
65535
seconds.
Normal status delay
: Normal status delay
defines a period for which the device needs
to be back in normal orientation, before
restoring normal status. The normal status
delay period is useful to prevent restoring
the normal status and cancelling man down
alert by accident. Normal status delay can
be set
1
-
65535
seconds.
Config 41: Man down alert angle
Defines the value for angle to be used if man
down alert mode is defined in
config 39: man
down mode on page 31
.