Operating instructions
played.
"Post-emergency mode". The GSM operator´s
name is replaced by the emergency symbol.
While this notification is shown, the device can
be tracked by emergency numbers, also
emergency tone and display settings are kept
on. This mode can be terminated manually, by
pressing the END key.
NETWORK EMERGENCY CALL (112, 911, 000, 999, 08 etc)
Network emergency call query. Shown when
the TWIG SOS button is pressed but making
emergency cycle is NOT possible (e.g. SIM
card is missing or no roaming network
available). You may still try to make network
emergency call by pressing SEND KEY. You
can also exit the query without making an
emergency call by pressing END KEY
DISCREET EMERGENCY CYCLE (DISPLAY NOTIFICATIONS
OFF)
During the discreet emergency cycle, the device
looks like it is in stand-by mode. The only indicator
of the ongoing emergency cycle is the Emergency
cycle indicator appearing to icon area. When the
icon disappears / changes the cycle is over or
moved to post emergency mode. Also tones can
be turned off.
NOTIFICATIONS REFERRING SENSOR ALERTS
Pre-alarm for sensor alert is NOT set. Shown
when "the cancel timer" is not configured, and
Emergency cycle starts right away. To mute
the audible alert tone, press the END key
Pre-alarm for sensor alert is set. The
countdown timer shows that you still have 27
seconds time left to cancel the sensor alert if
you so desire.
To cancel the emergency cycle, lift the device
to vertical position. Do it while this notification
is shown. To let the emergency cycle take
place: Do nothing. To mute the audible alert
tone, press the number 1 key
Alert state ended. Shown right after the
emergency cycle is finished, or the sensor
alert is cancelled.
Post-alarm state. Shown when the
emergency cycle is completed, and the
device makes audible alarms at regular
intervals. You can receive phone calls and
answer them by pressing SEND. In order to
stop the post-alarm tone press END key.
NOTIFICATIONS REFERRING AMBER ALERT / COND CHECK
Keep pressing to activate Amber Alert /
Condition check
10
Timer value. Adjust with keya 1 and 2 in 10
minute increments.
Press 1 to cancel Amber Alert / Condition
check mode. Press 2 to ignore.
BASIC KEY FUNCTIONS
TURNING THE DEVICE ON
1. Press END KEY and hold it down for a few seconds.
2. The logo is shown.
TURNING THE DEVICE OFF
1. Press the END KEY and hold it down for a few seconds.
2. The logo is shown and the Power down tone is heard.
ADJUSTING VOLUME DURING A CALL
Press the 1 and 2 keys during call, 1 to lower and 2 to rise the
volume .
ANSWERING INCOMING CALLS
Press the SEND KEY key when the device alerts.
NOTE: The device may be configured to answer some/all
incoming calls automatically. It may even be, that all incoming
calls are bloked and you can not receive calls.
DROPPING/ENDING/CANCELLING A CALL
Press the END KEY briefly.
MAKING AN INFORMATION CALL
Press the corresponding number key and hold it down for a few
seconds. The device will call to configured number.
SENDING POSITION REPORT
1. Press the corresponding number key and hold it down for a
few seconds.
2. After sending the position report, the device may receive an
incoming information call - depending on service.
3. When the device starts alerting, answer the call by pressing
the SEND KEY.
NOTE: The device may also be configured to answer the call
automatically.
MAKING EMERGENCY CALLS AND SENDING
EMERGENCY MESSAGES (EMERGENCY CYCLE)
Press the TWIG SOS button according to configuration (a long
press/ two quick presses). The device will make emergency
calls and send emergency reports (emergency messages
including position information) according to configuration.
CANCELLING EMERGENCY CYCLE
During cancellation period you may hear the cancellation tone
and see timer showing time left for cancellation.
•To cancel the entire emergency cycle, press the END KEY
briefly
during the cancellation period.
•When the emergency cycle has already started you may,
depending on configuration still cancel the rest of the calls and
messages: Press the END KEY and hold it down for several seconds.
After successful cancellation the device will return to normal operation
and switch back to normal tone and display settings.
ENDING EMERGENCY MODE MANUALLY
The emergency mode must be terminated manually. This means, the
emergency tone settings are kept on and the emergency numbers are
permitted to track the device without further notice.
Emergency tones and tracking option are switched on from the
moment you start the emergency cycle (by pressing the TWIG SOS
button) until you end the emergency mode (by pressing the END KEY
briefly). Another alarm cycle is not possible before previous is
ended.
SOME CIRCUMSTANCES MAY AFFECT ON EMERGENCY
CYCLE AND MODE
•Being in a shadow area of the GSM network at the time of the event.
•Poor GPS coverage during emergency cycle may cause the
emergency cycle completion to slow down.
•Busy telephone lines when connecting (voice) calls.
•Message transmission errors caused by the carrier of an SMS/GPRS,
i.e. the network operator.
SENSOR ALERTS
To cancel sensor alert and prevent emergency cycle from starting,
change the phone to allowed position (horizontal or vertical) or move it
gently if it is configured to detect only movement. Do it while the
countdown timer is still shown.
To let the emergency cycle take place: Do nothing. To mute the
audible alert tone, press the 1 key
INCOMING/OUTGOING MPTP MESSAGES
The device may send or receive some MPTP messages. In most
cases messages are either remote configuration/activation messages,
some notifications, emergency reports or various types of position
messages and they work autonomously according to configuration.
•In most cases there are no display notifications.
•Message sending/reception tones are configurable (beep sound as a
default).
AMBER ALERT /CONDITION CHECK
1. Press the activation key ( number 3) and hold it down for a few
seconds.
2. Device will prompt default timer value. Value can be adjusted with
keys 1 and 2.
3. Press number 3 again to confirm and activate timer. If the function is
in local mode it will start immediately but if the mode is interactive it
requires acknowledgement from control centre.
Once the timer pre-alarm time expires, user must acknowledge and
reset the timer. Failure will activate the Emergency Cycle.
MAN DOWN ALERT CONTROL
Toggle Man Down function ON/OFF with button 4 if allowed by Your
Service Provider.