3. Once the air line hose route has reached the Left
Ramp Assembly’s Rear Safety, cut the air line hose and
connect a Tee  tting to the air line end. (See Fig 7.2)
4. Connect a short section of the air line from the Rear
Safety to the Tee  tting.
5. Route the air line hose down the left hand hose trough
and through the  oor cover to the opening for the right
hand hose trough. (See Fig 7.3)
6. Cut the line and attach a Tee  tting.
7. Repeat items 1-5 for the Right Ramp Assembly.
8. Connect the air line from the Right Ramp Assembly to
the Tee  tting from item 6.
9. Route the air line into the Power Unit Console and con-
nect it to the Air Push Button. (See Fig 7.4)
10. Connect the Air Push Button to your compressed air
supply. Be sure that your compressed air supply does not
exceed 125 PSI.
STEP 8
(Power Unit Electrical Connection)
1. The standard power unit for your lift is 220 volt, 60HZ,
single phase. All wiring must be performed by a certi ed
electrician only. SEE WIRING INSTRUCTIONS AFFIXED
TO MOTOR FOR PROPER WIRING INSTRUCTIONS.
2. Route Power Cable through the hole in rear of Power
Unit Console.
Note: Scissor arm hidden for clarity.
Fig 7.2
Tee Fitting
Fig 7.3
Hose
Troughs
Fig 7.4
Air Supply In
Air Line
Connection
DANGER !
ALL WIRING MUST BE PERFORMED
BY A LICENSED ELECTRICIAN.
DANGER!
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS WITHOUT
FIRST ENSURING THAT ELECTRICAL POWER HAS
BEEN DISCONNECTED AT THE SOURCE OR PANEL
AND CANNOT BE RE-ENERGIZED UNTIL ALL
MAINTENANCE AND/OR INSTALLATION
PROCEDURES ARE COMPLETED.
WARNING!
DO NOT RUN POWER UNIT WITHOUT OIL. DAMAGE TO
POWER UNIT PUMP CAN OCCUR. THE POWER UNIT
MUST BE KEPT DRY. DAMAGE TO POWER UNIT CAUSED
BY WATER OR OTHER LIQUIDS SUCH AS DETERGENTS,
ACID ETC., IS NOT COVERED UNDER WARRANTY.
OPERATE LIFT ONLY BETWEEN TEMPERATURES OF
41 °- 104° F. IMPROPER ELECTRICAL HOOK-UP CAN
DAMAGE MOTOR AND WILL NOT BE COVERED UNDER
WARRANTY. MOTOR CAN NOT RUN ON 50HZ WITHOUT
A PHYSICAL CHANGE IN THE MOTOR.
USE A SEPARATE CIRCUIT BREAKER FOR EACH POWER
UNIT. PROTECT EACH CIRCUIT WITH TIME DELAY FUSE
OR CIRCUIT BREAKER.
FOR 208-230 VOLT, SINGLE PHASE, USE A 25 AMP FUSE.
FOR 208-230 VOLT, THREE PHASE, USE A 20 AMP FUSE.
FOR 380-440 VOLT, THREE PHASE, USE A 15 AMP FUSE.