Product Manual

14
STEP 7
(Mounting the Hydraulic Power Unit)
1. Attach the power unit to the POWER SIDE Column.
Install the vibration dampener between the power unit and
the power unit mounting plate on the Power Side Column,
using four M8 hex head bolts and nuts supplied.
(See Fig 7.1)
2. Fill the reservoir with 10 WT. HYDRAULIC OIL OR
DEXRON TYPE III ATF, approximately four gallons. Make
sure the funnel used to ll the Power Unit is clean.
Do not connect power unit hydraulic hose assembly at
this time.
3. The standard power unit for your lift is 220 volt, 60HZ,
single phase. All wiring must be performed by a certied
electrician only. SEE WIRING INSTRUCTIONS AFFIXED
TO MOTOR FOR PROPER WIRING INSTRUCTIONS.
STEP 8
(Installing the Safeties and Safety Cable)
1. Install safety weldments on to each respective
Column. (See Figs 8.1 - 8. 2)
Fig 7.1
Vibration Dampener
M8 x1.25 x 35mm
hex head bolts, M8
at washers and
M8 Nylock nuts
(Qty 4 ea)
ALL WIRING MUST BE PERFORMED
BY A LICENSED ELECTRICIAN.
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS WITHOUT
FIRST ENSURING THAT ELECTRICAL POWER HAS
BEEN DISCONNECTED AT THE SOURCE OR
PANEL AND CANNOT BE RE-ENERGIZED UNTIL
ALL MAINTENANCE AND/OR INSTALLATION
PROCEDURES ARE COMPLETED.
DO NOT RUN POWER UNIT WITHOUT OIL. DAMAGE
TO POWER UNIT PUMP CAN OCCUR. THE POWER
UNIT MUST BE KEPT DRY. DAMAGE TO POWER UNIT
CAUSED BY WATER OR OTHER LIQUIDS SUCH AS
DETERGENTS, ACID ETC., IS NOT COVERED
UNDER WARRANTY.
OPERATE LIFT ONLY BETWEEN TEMPERATURES
OF 41 °- 104° F. IMPROPER ELECTRICAL HOOK-UP
CAN DAMAGE MOTOR AND WILL NOT BE COVERED
UNDER WARRANTY. MOTOR CAN NOT RUN ON 50HZ
WITHOUT A PHYSICAL CHANGE IN THE MOTOR.
USE A SEPARATE CIRCUIT BREAKER FOR EACH
POWER UNIT. PROTECT EACH CIRCUIT WITH TIME
DELAY FUSE OR CIRCUIT BREAKER.
FOR 208-230 VOLT, SINGLE PHASE, USE A 25 AMP FUSE.
FOR 208-230 VOLT, THREE PHASE, USE A 20 AMP FUSE.
FOR 380-440 VOLT, THREE PHASE, USE A 15 AMP FUSE.
Safety
Cable
Hairpin
Cotter
Power Side
Safety Weldment
Torsion
Springs
Safety
Clevis
Pin
Fig 8.1