Product Manual

12
SITE LAYOUT / FLOOR PLAN
Model A Capacity
XPR-12FDL 155” / 3937 mm 12,000 LBS
A
STEP 4
(Site Layout)
1. Determine which side of the lift will be the approach side.
2. Now determine where the power unit will be located.
The POWER SIDE column has the power unit mounting
bracket attached to the side.
3. Use the chart on this page to determine which lift width
layout you would like to use.
4. Once a location is determined, use a carpenters chalk
line to layout a grid for the Column locations. Keep all
dimensions square within 1/8” (3mm) or malfunctioning of
the lift can occur.
5. After the Column locations are properly marked, use
chalk or crayon to make an outline of the posts on the oor
at each Column location using the Column base plates as
a template.
(See Fig 4.1)
6. CHECK ALL DIMENSIONS TWICE and make sure that
the layout is perfectly square.
CHALK LINE
Fig 4.1