Product Manual
P-9000LT/F Low-Rise Pit Lift 38 P/N 5900022 — Rev. A5 — February 2019
Maintenance
⚠ DANGER Before performing any maintenance, make sure the Lift is completely disconnected
from power and
cannot
be re-energized until all maintenance is complete.
BendPak strongly recommends using your Power Disconnect Switch during
maintenance.
To maintain your Lift:
• Daily: Keep the Lift clean. Wipe up any oil spills, clean any dirt.
• Daily: Make a visual inspection of all moving parts and check for damage or excessive wear. If
you find any damaged or worn parts, take the Lift out of service until they are replaced.
• Daily: Make sure the Safety Locks are in good operating condition. If you find that the Safety
Locks are damaged or excessively worn, take the Lift out of service until they are replaced.
Do
not use your Lift if the Safety Locks are damaged or excessively worn
.
• Weekly: Check all controls to make sure they are functioning normally.
• Weekly: Check all labels on the unit. Replace them if they are illegible or missing.
• Monthly: Lubricate the grease fittings. We recommend using white lithium grease or similar.
• Monthly: Check the Power Unit’s Hydraulic Fluid levels. Refill if low.
• Every two months: Check all Anchor Bolts to make sure they are tight. If not, tighten them.
⚠ WARNING: Do not operate your Lift if you find issues; instead, take the lift out of service, then
contact your dealer, email techsupport@bendpak.com, visit
bendpak.com/support, or call (800) 253-2363, extension 196.