Product Manual

P-9000LT/F Low-Rise Pit Lift 28 P/N 5900022Rev. A5 February 2019
Connect the Power Unit
The Power Unit comes fully assembled from the factory. You need to attach it to the back of the
Console (described in Set Up the Console and Attach the Power Unit) and then make
additional connections, described in this section.
The Power Unit for the P-9000LT is 208-240 VAC, 50/60 Hz, 1 phase. The Hydraulic Fluid Reservoir
holds 6 liters (1.6 gallons) of fluid.
DANGER All wiring
must
be performed by a licensed, certified electrician.
Refer to Wiring Diagram for power source wiring information.
CAUTION The Power Unit’s motor is
not
thermally protected.
The Power Unit has multiple connections:
Hydraulic Lines. The Lift has two Hydraulic Lines. They both connect to the Power Unit on its
Hydraulic Power Out connectors (labelled P1 and P2).
Controls. The Power Unit connects to the controls on the top of the Console via a female
(Molex™) connector.
Power Source. The Power Unit connects to an appropriate, incoming power source. A licensed,
certified electrician is
required
to make this connection.
The following drawing shows the Power Unit of the P-9000LT/F.
Drawing is not necessarily to scale. Your Power Unit may be slightly different.