Product Manual

P-9000LT/F Low-Rise Pit Lift 24 P/N 5900022Rev. A5 February 2019
4. Remove the Shipping Plugs from the Hydraulic Line Ports at the bottom of each Hydraulic
Cylinder.
5. Attach an Hydraulic Elbow Fitting to each of the Hydraulic Line Ports at the bottoms of each of the
Hydraulic Cylinders.
6. Attach the Short End of either of the Hydraulic Line Assemblies to one of the Hydraulic Elbow
Fittings you just attached, then attach the Short End of the other Hydraulic Line Assembly to the
other Hydraulic Elbow Fitting.
CAUTION When installing the Hydraulic Line Assemblies, make sure they are angled so they
end up against or very near to the Hydraulic Cylinders, not standing straight up.
Drawing not to scale. Some components not shown, other components exaggerated for clarity.
Fittings shown not connected for clarity.
Finger tighten the connections.
7. Route one of the two Hydraulic Lines from the Long End of one of the Hydraulic Line Assemblies,
through the Retaining Rings in the corners of each Base, into an opening in the bottom of the
Console, then up to one of the Hydraulic Power Out connectors on the Power Unit.
8. When the Hydraulic Line is correctly routed, connect it at both ends to the appropriate fittings.
Finger tighten the connections.
9. Perform Steps 7 and 8 for the second Hydraulic Line.
10. Make sure both Hydraulic Lines are correctly routed and do not have any kinks, then use
appropriate tools to
securely