Use and Care Manual
Table Of Contents
- HD-9 Manual
- Table of Contents
- Introduction
- Shipping Information
- Safety Considerations
- Components
- Specifications
- Frequently Asked Questions
- Installation Checklist
- Installation
- Being Safe
- Using Tools
- Planning for Electrical Work
- Selecting a Location
- Checking Clearances
- Deciding the Lift Orientation
- Creating Chalk Line Guides
- Unloading and Unpacking
- Moving the Posts into Position
- Installing the Crosstubes
- About Safety Locks
- Installing the Ladders and Top Cap
- Raising the Crosstubes
- Securing the Ladders
- Removing the Sheaves
- Installing the Runways
- Installing the First End of the Flex Tube
- Routing the Lifting Cables
- Working with Compression Fittings and Tubing
- Installing the Air Lines
- Installing the Return Line
- Hydraulic Fluid Contamination
- About Thread Sealants
- Installing the Hydraulic Hose
- Installing the Power Unit
- Filling the Hydraulic Fluid Reservoir
- Installing the Second End of the Flex Tube
- Installing the Pushbutton Air Valve
- Connecting the Return Line
- Connecting the Hydraulic Hose
- Contacting the Electrician
- Connecting the Power Source
- Installing a Power Disconnect Switch
- Installing a Thermal Disconnect Switch
- About Effective Embedment
- Anchoring the Posts
- Final Leveling
- Installing Accessories
- Lubricating the Lift
- Bleeding the Hydraulic Cylinder
- Test the Lift
- Final Checklist
- Outdoor usage
- Operation
- Maintenance
- Troubleshooting
- Wiring Diagrams
- Labels
- Parts Drawings
- Automotive Lift Institute (ALI) Store
HD-9 Series Four-Post Lifts 44 P/N 5900123 — Rev. M1 — March 2020
About Thread Sealants
We recommend using a Liquid Thread Sealant (like Loctite™ 5452 or similar PTFE Thread Sealant) to
seal the Hydraulic components on your Lift.
Liquid Thread Sealant lubricates and fills the gaps between the Fitting threads, and leaves no residue
that could contaminate the Hydraulic Fluid. Other types of Thread Sealants (like Teflon Tape) can shred
during installation or removal and eventually enter the Hydraulic System.
Thread Sealant is not the same as a
Threadlocker
; Threadlocker holds assemblies tightly in
place to prevent them from loosening over time, and is not easily removed.
Thread Sealant can be used with most Hydraulic Fittings, although you probably only need to use it
with NPT connectors.
To apply Thread Sealant:
1. Make sure the Fittings and connectors you are going to use are clean and dry.
If you are adding Thread Sealant to a Fitting or connector that has already been used with a
different Sealant, use a wire brush to thoroughly remove the old sealant before adding more.
2. Apply a small amount of Thread Sealant to the first four threads of the Fitting.
⚠ WARNING Always wear the proper protective equipment when handling Thread Sealant.
You only need a small amount because the sealant spreads to the other threads as it is tightened
into place.
If you put too much, the excess liquid will be pushed out when the Fitting is tightened; use a rag to
wipe the excess.
3. Tighten the Fitting into the connector; do
not
over tighten the Fitting.
4. Allow the manufacturer-recommended curing time before pressurizing the system.