Full Product Manual

MD-6XP Mid-Rise Scissor Lift 28 P/N 5900108Rev. F2 April 2021
Maintenance
DANGER Before performing maintenance on your Lift, make sure it is disconnected from
power. The Lift uses electrical energy; if your organization has Lockout/Tagout
policies, make sure to implement them before performing any maintenance. If you
come into contact with high voltage/current, you could be injured or killed.
To maintain your Lift:
Daily: Keep the Lift clean. Wipe up any oil spills, clean any dirt.
Daily: Make a visual inspection of all moving parts and check for damage or excessive wear. If
you find any damaged or worn parts, take the Lift out of service until they are replaced.
Daily: Make sure the Safety Locks are in good operating condition. If you find that the Safety
Locks are damaged or excessively worn, take the Lift out of service until they are replaced.
Do
not use your Lift if the Safety Locks are damaged or excessively worn
.
Weekly: Check all controls to make sure they are functioning normally.
Weekly: Check all labels on the unit. Replace them if they are illegible or missing.
Monthly: Lubricate the grease fittings. We recommend using white lithium grease or similar.
Monthly: Check the Power Unit’s Hydraulic Fluid levels. Refill if low.
WARNING: Do not operate your Lift if you find issues; instead, take it out of service, then
contact your dealer, email support@bendpak.com, visit