Contacting the Electrician
As mentioned previously, there are installation tasks that
require
a certified Electrician.
DANGER All wiring
must
be performed by a licensed, certified Electrician.
The Electrician needs to:
Connect the Power Unit to an appropriate power source. A power source is required.
Refer to Connecting to a Power Source for more information.
Install a Power Disconnect Switch. Ensures you can quickly and completely interrupt
electrical power to the Lift in the event of an electrical circuit fault, emergency situation, or when
equipment is undergoing service or maintenance. You must put it within sight and easy reach of
the Lift operator. Refer to Install a Power Disconnect Switch for more information.
Install a Thermal Disconnect Switch. Ensures the equipment shuts down in the event of an
overload or an overheated motor. Refer to Install a Thermal Disconnect Switch for more
information. Note that the Power Unit that comes with the Lift is
not
thermally protected.
The electrician is responsible for providing:
an appropriate cable and plug to attach to the Power Unit, for connection to a wall outlet
or
an
appropriate cable that attaches the Power Unit to the facility’s electrical system
a Power Disconnect Switch
a Thermal Disconnect Switch
Refer to Wiring Diagrams for wiring information for your Lift’s Power Unit.
Additional information is supplied in the sections describing these tasks.