Use and Care Manual
Table Of Contents
- Table of Contents
- Introduction
- Shipping Information
- Safety Considerations
- Components
- Specifications
- Installation Checklist
- Installation
- Reviewing the Safety Rules
- Gathering Your Tools
- Preparing for Electrical Work
- Reviewing the Installation Orientation
- Checking Clearances
- Selecting a Location
- Choosing a Wide or Narrow Configuration
- Installing the Safety Assemblies and Positioning the Safety Lock Cable
- Putting the Equalizing Cables into Position
- About Thread Sealants
- Identifying Hydraulic Fittings
- Routing the Hydraulic Hoses
- Creating Chalk Line Guides
- Anchoring the Posts
- Installing the Overhead Assembly and Safety Shutoff Bar
- Installing the Microswitch
- Completing the Equalizing Cables Installation
- Mounting the Power Unit
- Installing the Safety Lock Cable
- Connecting the Hydraulic Hoses
- Installing the Lift Arms
- Double Threaded Rod Installation
- Leveling
- Contact the Electrician
- Electrical Information
- Wiring the Microswitch
- Connecting the Power Unit
- Installing a Power Disconnect Switch
- Installing a Thermal Disconnect Switch
- Lubricating the Lift
- Review Final Checklist Before Operation
- Leave the Manual with the Owner/Operator
- Perform an Operational Test
- Operation
- Maintenance
- Troubleshooting
- Wiring Diagrams
- Labels
- Parts Drawings
- Automotive Lift Institute (ALI) Store
- Maintenance Log
- Maintenance Log
10AP Series Two-Post Lifts 51 P/N 5900265 — Rev. A10 — September 2023
Contact the Electrician
As mentioned previously, there are installation tasks that require a certified Electrician.
⚠ DANGER All wiring must be performed by a licensed, certified Electrician in accordance with
all applicable local electrical codes.
The Electrician needs to:
• Connect to power. The Power Unit comes with a pigtail for wiring to a power source. Have your
Electrician connect a power cord with plug to the electrical box on the Lift (for connection to a
power outlet) or have them wire it directly into the electrical system at the Lift location.
• Connect the Microswitch to the Power Unit. The Microswitch (which is next to the Safety
Shutoff Bar) must be wired to the Power Unit. The necessary wiring is included.
• Install a Power Disconnect Switch. Ensures you can quickly and completely interrupt
electrical power to the Lift in the event of an electrical circuit fault, emergency, or when equipment
is undergoing service or maintenance. You must put it within sight and easy reach of the Lift
operator. Refer to Installing a Power Disconnect Switch for more information.
• Install a Thermal Disconnect Switch. Ensures the equipment shuts down in the event of an
overload or an overheated motor. Refer to Installing a Thermal Disconnect Switch for
more information.
These installation tasks are described in detail in the following sections.
The Electrician is responsible for providing:
• A power cord and appropriate 220 VAC plug for connecting to an appropriate power source or the
items required to connect to the facility’s power system
• a Power Disconnect Switch
• a Thermal Disconnect Switch
Additional information is supplied in the following sections describing these tasks.
Electrical Information
⚠ DANGER All wiring must be performed by a licensed, certified Electrician in accordance with
all applicable local electrical codes. Do not perform any maintenance until main
electrical power has been disconnected from the Lift and cannot be re-energized
until all procedures are complete.
Important electrical information:
• Improper electrical installation can damage the Power Unit motor, which is not covered by the
warranty.
• The Lift uses electrical energy; if your organization has Lockout/Tagout policies, make sure to
implement them after connecting to a power source.
• Use a separate circuit breaker for each Power Unit.
• Protect each circuit with a time delay fuse or circuit breaker:
– For a 208 to 230 VAC,
single phase
circuit, protected by an appropriate fuse or circuit breaker
for the power unit delivered with the Lift.