Use and Care Manual

Table Of Contents
10AP Series Two-Post Lifts 45 P/N 5900265Rev. A10 September 2023
below). Do not connect to any of the other Ports and do not connect to more than one
Hydraulic Pressure Port.
The following drawing shows the possible Hydraulic Pressure Port locations, depending on the
Power Unit you have.
Tighten the Elbow Fitting appropriately; make sure to leave the 06 JIC connector facing up,
towards the Tee Fitting.
Connect the Curved End of the Short Hydraulic Hose to the Tee Fitting; finger tighten the
connection.
This connection is made on the outside of the Powerside Post. If the 06 JIC connector of the Tee
Fitting is not on the outside of the Powerside Post, this means the Tee Fitting was not installed
correctly. Return to Routing the Hydraulic Hoses for more information.
Connect the Straight End of the Short Hydraulic Hose on the Elbow Fitting; finger tighten the
connection.
Switching to the Offside Post, take the Long Hydraulic Hose and route it over the Overhead
Assembly towards the Powerside Post, making sure to put the hose through the Clips in the Post.
If you are installing the Lift in a Wide Configuration, you need to install the Short Hydraulic Hose to
the top of the Tee Hydraulic Fitting, and then install a Nipple Hydraulic Fitting (5550095) to the top
of the Short Hydraulic Hose.
The Short Hydraulic Hose is not used for Narrow Configurations.
Connect the Straight End of either the Long Hydraulic Hose (for Narrow Configurations) or the Very
Short Hydraulic Line (for Wide Configurations) to the 04 JIC connector facing up on the Tee
Hydraulic Fitting; finger tighten the connection.
Using appropriate tools, go back and securely tighten all the finger-tightened connections.