Use and Care Manual
Table Of Contents
- Table of Contents
- Introduction
- Shipping Information
- Safety Considerations
- Components
- Specifications
- Installation Checklist
- Installation
- Reviewing the Safety Rules
- Gathering Your Tools
- Preparing for Electrical Work
- Reviewing the Installation Orientation
- Checking Clearances
- Selecting a Location
- Choosing a Wide or Narrow Configuration
- Installing the Safety Assemblies and Positioning the Safety Lock Cable
- Putting the Equalizing Cables into Position
- About Thread Sealants
- Identifying Hydraulic Fittings
- Routing the Hydraulic Hoses
- Creating Chalk Line Guides
- Anchoring the Posts
- Installing the Overhead Assembly and Safety Shutoff Bar
- Installing the Microswitch
- Completing the Equalizing Cables Installation
- Mounting the Power Unit
- Installing the Safety Lock Cable
- Connecting the Hydraulic Hoses
- Installing the Lift Arms
- Double Threaded Rod Installation
- Leveling
- Contact the Electrician
- Electrical Information
- Wiring the Microswitch
- Connecting the Power Unit
- Installing a Power Disconnect Switch
- Installing a Thermal Disconnect Switch
- Lubricating the Lift
- Review Final Checklist Before Operation
- Leave the Manual with the Owner/Operator
- Perform an Operational Test
- Operation
- Maintenance
- Troubleshooting
- Wiring Diagrams
- Labels
- Parts Drawings
- Automotive Lift Institute (ALI) Store
- Maintenance Log
- Maintenance Log
10AP Series Two-Post Lifts 45 P/N 5900265 — Rev. A10 — September 2023
below). Do not connect to any of the other Ports and do not connect to more than one
Hydraulic Pressure Port.
The following drawing shows the possible Hydraulic Pressure Port locations, depending on the
Power Unit you have.
Tighten the Elbow Fitting appropriately; make sure to leave the 06 JIC connector facing up,
towards the Tee Fitting.
Connect the Curved End of the Short Hydraulic Hose to the Tee Fitting; finger tighten the
connection.
This connection is made on the outside of the Powerside Post. If the 06 JIC connector of the Tee
Fitting is not on the outside of the Powerside Post, this means the Tee Fitting was not installed
correctly. Return to Routing the Hydraulic Hoses for more information.
Connect the Straight End of the Short Hydraulic Hose on the Elbow Fitting; finger tighten the
connection.
Switching to the Offside Post, take the Long Hydraulic Hose and route it over the Overhead
Assembly towards the Powerside Post, making sure to put the hose through the Clips in the Post.
If you are installing the Lift in a Wide Configuration, you need to install the Short Hydraulic Hose to
the top of the Tee Hydraulic Fitting, and then install a Nipple Hydraulic Fitting (5550095) to the top
of the Short Hydraulic Hose.
The Short Hydraulic Hose is not used for Narrow Configurations.
Connect the Straight End of either the Long Hydraulic Hose (for Narrow Configurations) or the Very
Short Hydraulic Line (for Wide Configurations) to the 04 JIC connector facing up on the Tee
Hydraulic Fitting; finger tighten the connection.
Using appropriate tools, go back and securely tighten all the finger-tightened connections.