User guide

FPD 500 FLAT PANEL DISPLAY SYSTEM
EADI/EHSI Operation
2-1
Rev. 0
Dec/97
a
2. EADI/EHSI OPERATING CONTROLS
2.1 CONTROLS
The controls consist of a
BRT/DIM rocker switch, a TEST
button, four function buttons (“N”
NORM, “M” MODE, “R” RANGE,
“I” INTEGRATE), and an ambient
light sensor.
2.1.1 DISPLAY INTENSITY
Press the rocker switch on the BRT end to increase intensity
and on the DIM end to decrease intensity. The switch func-
tion is the same for both ADI and HSI.
2.1.2 TEST BUTTON
Pressing and holding the TEST button activates Self Test
and displays the test modes. The function is the same for
both ADI and HSI. Self Test is inhibited during ILS mode.
2.1.3 FUNCTION BUTTONS
2.1.3.1 “N” NORM Button
Pressing this button always reverts the display to Normal
mode (ADI or HSI).
2.1.3.2 “M” MODE Button
This button is non-functional in ADI mode. In HSI mode,
each press cycles the display between NORMAL, ARC, and
MAP. MAP modes are not currently active.
N
M
R
I
DIM
TEST
BRT
Figure 2-1
FPI Bezel
DIM
BRT
TEST
N
M