User guide

Maintenance Mode Displays
6-2
FPD 500 FLAT PANEL DISPLAY SYSTEM
Rev. 0
Dec/97
a
6.1 MAINTENANCE PAGE 1
The following is the definition of
the states for the page:
Parameter States
A/C TYPE B-727/DC-10
A/C SIDE CAPT/FO
DISPLAY TYPE ADI/HSI
CM ANNUN ON/OFF
FD CMD IN VIEW HI/LO
PITCH CMD 150/120
ROLL CMD 150/66
6.2 MAINTENANCE PAGE 2
The following is the definition of
the states for the page:
Parameter States
LAMP HEATER ON/OFF
LCD HEATER ON/OFF
A red flashing “FREEZE” annun-
ciation indicates that the status
annunciations are static with no
update, frozen by pressing the
Mode (M) button.
N
M
R
I
DIM
TEST
BRT
DU OPERATING PARAMS PG 02
INTERNAL TEMPERATURE 38 °C
EXTERNAL LIGHT LEVEL 120
DISPLAY BRIGHTNESS 25.46 FL
BURST CONTROL OUTPUT 23.50 %
DIM/HV OUTPUT 0.00 V
LAMP HEATER OFF
LCD HEATER OFF
TOTAL POWER CYCLES 303
TOTAL TIME 64 HRS
POWER CYCLE TIME 0 HRS 11 MINS
Figure 6.2-1
Maintenance Page 2
ITEST
FREEZE
Figure 6.2-2
Frozen Maintenance Page 2
N
M
R
I
DIM
TEST
BRT
FPI-3501B MAINTENANCE PG 01
COPYRIGHT
ALLIEDSIGNAL AVIONICS INC. 1995
SW RELEASE 01/2H ID 1230960925
BOOT RELEASE 01/02
S/N 0021
P/N 066-50017-0101
INSTALL/CONFIGURATION OPTIONS
A/C TYPE B-727
A/C SIDE CAPT
DISPLAY TYPE HSI
CM ANNUNCIATIONS OFF
FD CMD IN VIEW HI
PITCH CMD 150
ROLL CMD 150
Figure 6.1-1
Maintenance Page 1