Instruction manual
CHANNEL 0 GROUP ONE SETTINGS
1
pRG
y--
yc7395,
enabled or disabled.
After the scan delay time is set the LCD
will display
PRG l-12345.
This is a group
of five individual functions that can be
When a function is enabled, the
corresponding number in the display will
flash. When the function is disabled the
number is steady. To change the function
from enabled to disabled or vice versa,
press the number key corresponding to
that function. After making all the desired
changes for group one settings, press the
[ENT]
key to save your changes and
advance to the group two settings.
EXAMPLE: If function 4 (Priority Key
Lockout) is disabled, the 4 in the display
will not be flashing. If the
[4]
key is
pressed, the 4 in the display will flash,
signifying that Priority Key Lockout is
enabled. A subsequent press of the [4]
key will disable Priority Key Lockout.
BATTERY SAVER INHIBIT
When function 1 is enabled (flashing) the
battery saver is turned off . The battery
saver should be turned off only to get
proper voltage readings during service or
in systems requiring extremely fast squelch
attack time.
NOTE: Bendix/King current drain and battery life specifications are
based on performance with the battery saver on.
Keyboard Programming
7