Sensor Calibration
The Sensor Calibration page allows the Lateral Acceleration Sensor (LAS) to be calibrated. The trailer
needs to be on a level surface for the calibration. Press “Start” to begin the calibration process, use the
“Yes, No, or Cancel” choices to answer any questions. Bendix
®
ACom
®
Diagnostics software can be used
to recalibrate the lateral acceleration sensor, clear any DTCs and display the actual sensor value.
Figure 19
Control Buttons for TRSP Sensors:
• The Start button starts the calibration
• The Yes button is used to acknowledge that the technician is in agreement with the question asked
• The No button is used when the technician disagrees with the question asked
• The Cancel button stops the calibration
• The Close button closes the calibration window