User's Manual

60
APPENDIX C: UDS Codes and their Bendix Blink Code Equivalents
UDS
Code
US-
Spec.
Blink
Code
J1587
PID194
(SID/
FMI)
J1939/73
DM1/2
SPN/FMI
DTC Description
Lamp
Status
ABS
ATC/
ESP
201 15-06 006-08 0794-08 AA Right WSS Erratic Sensor Signal ON ON
202 15-04 006-10 0794-10 AA Right WSS Loss of Sensor Signal ON ON
205 20-03 066-05 1056-05 Trailer PMV REL Solenoid Open Circuit - ON
206 20-01 066-04 1056-04 Trailer PMV REL Solenoid Shorted to Ground - ON
207 20-02 066-03 1056-03 Trailer PMV REL Solenoid Shorted to Voltage ON ON
209 12-06 023-02 0811-02 ABS Indicator Lamp Circuit ON -
210 12-10 079-13 1069-13 Tire Size Out of Range (Front to Rear) ON ON
212 12-11 022-07 0810-07 Wheel Speed Sensors Reversed on an Axle ON ON
213 12-01 055-07 1045-07 Stop Lamp Switch Not Detected - ON
214 12-03 017-14 0576-14 ATC Disabled or Dynamometer Test Mode Active - ON
216 12-02 055-02 1045-02 Stop Lamp Switch Defective ON ON
220 12-13 102-03 0564-03 Diff Lock Solenoid Shorted to Voltage (total shutdown) ON ON
221 12-12 102-05 0564-05 Diff Lock Shorted to Ground or Open Circuit ON -
225 16-06 046-05 0799-05 AA Left PMV HLD Solenoid Open Circuit ON ON
226 16-04 046-04 0799-04 AA Left PMV HLD Solenoid Shorted to Ground ON ON
227 16-05 046-03 0799-03 AA Left PMV HLD Solenoid Shorted to Voltage ON ON
228 16-07 011-05 0799-05 AA Left PMV CMN Open Circuit ON ON
229 16-03 052-05 0799-05 AA Left PMV REL Solenoid Open Circuit ON ON
230 16-01 052-04 0799-04 AA Left PMV REL Solenoid Shorted to Ground ON ON
231 16-02 052-03 0799-03 AA Left PMV REL Solenoid Shorted to Voltage ON ON
232 11-13 231-02 0639-02 timeout or invalid data on J1939 AWD params for ESP AWD
operation
- ON
237 16-08 011-13 0799-13 AA Left PMV Conguration Error ON ON
238 13-26 155-14 0615-14 Maximum number of PCV cycles reached - -
239 13-27 155-14 0615-14 Maximum number of TCV cycles reached - -
240 23-01 099-02 1809-02 LAS Signal Out of Range - ON
241 17-06 047-05 0800-05 AA Right PMV HLD Solenoid Open Circuit ON ON
242 17-04 047-04 0800-04 AA Right PMV HLD Solenoid Shorted to Ground ON ON
243 17-05 047-03 0800-03 AA Right PMV HLD Solenoid Shorted to Voltage ON ON
244 17-07 012-05 0800-05 AA Right PMV CMN Open Circuit ON ON
245 17-03 053-05 0800-05 AA Right PMV REL Solenoid Open Circuit ON ON
246 17-01 053-04 0800-04 AA Right PMV REL Solenoid Shorted to Ground ON ON
247 17-02 053-03 0800-03 AA Right PMV REL Solenoid Shorted to Voltage ON ON
248 23-04 099-02 1809-02 LAS Long Term Calibration Error - ON
249 23-03 099-02 1809-02 LAS Static Calibration Error - ON
250 23-05 099-02 1809-02 LAS Plausibility Error (Inside Model Based Limits) - ON
251 23-06 099-02 1809-02 LAS Plausibility Error (Outside Model Based Limits) - ON
253 17-08 012-13 0800-13 AA Right PMV Conguration Error ON ON
SD-13-4869_US_003 © 2013 Bendix Commercial Vehicle Systems LLC • All Rights Reserved • 6/13
Log-on and Learn from the Best
On-line training that's available when you are 24/7/365.
Visit www.brake-school.com.