Operator`s manual

37
Section E: Additional Component Details
6.0 SmarTire Trailer-Link
System Component Details
6.1 SmarTire Trailer-Link Module Specications
6.1.1 Power, Mounting, and Environmental Requirements
Operating voltage range 9 – 36V
Typical current consumption (with no external loads) 30mA
5A fuse is required between the main power line of the trailer link and
the vehicle battery
Frequency 433.92 MHz
Modulation type: OOK
Design protected for FSK
500 kHz Band Width
Sensitivity (OOK) at 433.92 MHz : -112 dBm
Internal antenna only
Uses standard Deutsch enclosure
Tested to SAE J1455 Specications
Operating temperature range: -40C to +85C
Survivability temperature range: -40C to +85C
Sealed to IP67
Preferred mounting orientation to shed water is vertical (Connector side
facing rear of trailer, away from driving direction)
Preferred Mounting hardware: ¼ -20 (M6X1) Flange Head CAPSCREW,
torque to 7-10 FT/LBS (13 Nm)
The SmarTire Trailer-Link ECU has an internal antenna and should be
mounted free of any metal (only half the enclosure should be covered
by the chassis or metal bracket)