User manual

Chapter 8 Sample PLC-5 Program
76
ADVANCED MICRO CONTROLS INC.
Thu Feb 22, 1996 Page 6
Program Listing Report PLC-5/11 File 2762_17 Rung 2:13
Rung 2:13
The following three rungs are used to determine the channel 1 output status of
an AMCI 2762-17 module from the Input Image Table motion status bits. These
three rungs should be used when the direction parameter is set to "n" or CCW
increasing readings.
| comment |
| coil |
| N7:0 |
+----------------------------------------------------------------------( )-----+
| 0 |
Rung 2:14
| 2762-17 |2762-17 |2762-17 2762-17 |indicates |
| motion |motion |motion motion |forward |
| status bit|status bit|status bit status bit|motion |
| |output |
| |active |
| I:007 I:007 I:007 I:007 B3 |
+----]/[----+---]/[--------] [-----+-------------------+---]/[--------( )----+-+
| 03 | 02 01 | | 00 33 | |
| |2762-17 |2762-17 | |2762-17 |indicates | |
| |motion |motion | |motion |reverse | |
| |status bit|status bit | |status bit|motion | |
| | I:007 I:007 | | |output | |
| +---] [----+---]/[----++ | |active | |
| 02 | 01 | | I:007 B3 | |
| |2762-17 | +---] [--------( )----+ |
| |motion | 00 32 |
| |status bit| |
| | I:007 | |
| +---] [----+ |
| 01 |
Rung 2:15
| 2762-17 |2762-17 |2762-17 indicates |
| motion |motion |motion 2762-17 |
| status bit|status bit|status bit high speed |
| output |
| active |
| I:007 I:007 I:007 B3 |
+----]/[--------] [--------] [-----------------------------------------( )-----+
| 03 02 01 34 |