User manual
Chapter 6 Block Transfer Programming
ADVANCED MICRO CONTROLS INC.
61
Transducer Setup Read Back Data
When you send an Auxiliary Commands command with the RTS (Read Transducer Setup)
bit set, the 2762-17 responds by echoing back the Transducer Setup data. The Channel
Number bit (bit 00) of the Auxiliary Commands command determines which transducer data is
set. Therefore it requires two BTW/BTR sequences to read all of the Transducer Setup data.
The format of the data is shown below in figure 6.7. Note that read back data has bit 15 of
word 0 set to '1'.
15 14 13 12 10 09 08 07 06 05 04 03 02 01 0011
Transducer Setup Read Back
0001 000100
ChNm
TType
Decimal
Point
DIR
Lower 3 digits: Scale Factor
Word 1
Upper 1, 2 or 3 digits: Scale Factor
Number of Turns
Word 0
Lower 3 digits: Linear Offset
Upper 1, 2 or 3 digits: Linear Offset
SGN
Word 2
Word 3
Word 4
Word 5
Word 6
Word 7
Word 8
Word 9
Word 10
Word 11
Lower 3 digits: Preset Value
Upper 1, 2 or 3 digits: Preset Value
SGN
Lower 3 digits: Upper Travel Limit
Upper 1, 2 or 3 digits: Upper Travel Limit
SGN
Upper 1, 2 or 3 digits: Lower Travel Limit
SGN
Lower 3 digits: Lower Travel Limit
Fig 6.7 Read Back Transducer Setup Data