Positioning Setup Submenu
The Positioning Setup submenu contains all of the positioning setup parameters except for
Target Position and Positioning Direction. The figure below show all of the displays as they
appear on the module. Default values and range of values are also listed.
PLC SERIES
PLC SERIES
[
ENTER
]
Positioning Setup Menu
Press
[
FUNCTION
]
or
[å]
to advance to the
Run Profile menu. Press
[ä]
to return to the
Transducer Setup menu.
Returns to
Positioning Setup
Menu
[
FUNCTION
]
Overshoot Offset Parameter
Default: 1,000
Range: (Low Speed Offset + 1) to Full Scale Count
PLC SERIES
Low Speed Offset Parameter
Default: 500
Range: 0 and
(Stop Offset + 1) to (Overshoot Offset - 1)
Stop Offset Parameter
Default: 100
Range: 1 to (Overshoot Offset - 1) if Low Speed = 0
1 to (Low Speed - 1) if Low Speed
0
[
FUNCTION
]
Target Range Parameter
Default: 0
Range: 0 to Full Scale Count
[
FUNCTION
]
[
FUNCTION
]
PLC SERIES
PLC SERIES
FSC: Full Scale Count = (Transducer Type {100 or 180} * (Scale Factor/Number of Turns)) - 1