User manual
Chapter 2 2762-17 Module Description
ADVANCED MICRO CONTROLS INC.
27
Transducer Setup Submenu
The Transducer Setup submenu contains all of the transducer setup parameters. The figure
below and on the following page show all of the displays as they appear on the module.
Default values, range of values and any special programming instructions are also listed.
PLC SERIES
PLC SERIES
[
ENTER
]
Transducer Setup Menu
Press
[
FUNCTION
]
or
[å]
to advance to the
Positioning Setup Menu. Press
[ä]
to return
to the Tachometer Display.
Transducer Type Parameter
0 = HTT-20-100 or HTT-20-1000 Transducer
1 = HTT-20-180 or HTT-20-1800 Transducer
Press
[
s
]
or
[
t
]
to change transducer type. Press
[
ENTER
]
to accept the value. Press
[
FUNCTION
]
to
accept the value without changes.
WARNIN
:
Pressing
[
ENTER
]
while displaying this
parameter will reset all other Transducer Setup
Parameters to their default values.
PLC SERIES
PLC SERIES
Count Direction Parameter
P = Clockwise increasing count
n = Counter-clockwise increasing count
Decimal Point Parameter
Default: 0
Range: 0 to 5 inclusive.
[
FUNCTION
]
Continued on Pg 2-8
[
FUNCTION
]
PLC SERIES
Number of Turns Parameter
Default: 180.0 turns
Range: HTT-20-180: 0.1 to 180.0, 0.1 turn resolution
HTT-20-100: 0.1 to 100.0, 0.1 turn resolution
[
FUNCTION
]
[