7 Antilock application check list
This checklist is provided to assist in the verification of the ABS installation. It remains the
responsibility of the vehicle manufacturer to ensure system performance through the performance
of an EOL test.
Trailer ABS System Configuration
• Is the correct Trailer ABS ECU(s) selected for the specific trailer application? (e.g.
4S/2M axle control for full trailer)
Yes No Don’t Know
Trailer ABS Assembly (ECU/Modulator Relay Valve)
• Is the location of the assembly such that will not be subjected to direct wheel spray?
Yes No Don’t Know
• Is the location of the assembly such that will not be subjected to temperatures less
than -40 °F or greater +185 °F?
Yes No Don’t Know
• Is the exhaust port of the assembly facing in a downward direction?
Yes No Don’t Know
• Is the exhaust port of the assembly unobstructed with significant free space below (>
1 inch)?
Yes No Don’t Know
• Were all tube / brake hose fittings installed per the recommended manufacture's
specification?
Yes No Don’t Know
• Are all unused delivery ports of the assembly plugged?
Yes No Don’t Know
• For reservoir-mounted installations:
− Is a heavy gauge steel nipple (Schedule 80) being used between the assembly's
supply port and the reservoir?
Yes No Don’t Know
− Were following torque specifications used when installing pipe nipples?
Finger tight plus 1-1/2 turns with thread sealant
Finger tight plus 2 turns without thread sealant
Yes No Don’t Know
• For frame-mounted installation:
− Were the mounting fasteners torque's per the recommended manufacture's
specification?
Yes No Don’t Know
− Is a minimum 5/8" tube fitting being used for the assembly's supply port?
Yes No Don’t Know
Remote Modulator Relay Valve
• Is the location of the assembly such that will not be subjected to direct wheel spray?
Yes No Don’t Know
• Is the location of the assembly such that will not be subjected to temperatures less
than -40 °F or greater +185 °F?
Yes No Don’t Know
• Is the exhaust port of the assembly facing in a downward direction?
Yes No Don’t Know
• Is the exhaust port of the assembly unobstructed with significant free space below (>
1 inch)?
Yes No Don’t Know
• Were all tube / brake hose fittings installed per the recommended manufacture's
specification?
Yes No Don’t Know
• Are all unused delivery ports of the assembly plugged?
Yes No Don’t Know
• For reservoir-mounted installations:
− Is a heavy gauge steel nipple (Schedule 80) being used between the assembly's
supply port and the reservoir?
Yes No Don’t Know
− Were following torque specifications used when installing pipe nipples?
Finger tight plus 1-1/2 turns with thread sealant
Finger tight plus 2 turns without thread sealant
Yes No Don’t Know
• For frame-mounted installation:
− Were the mounting fasteners torque's per the recommended manufacture's
specification?
Yes No Don’t Know
− Is a minimum 5/8" tube fitting being used for the assembly's supply port?
Yes No Don’t Know
Table 17: TABS6 OEM Application Check-List