Specifications

CONFIDENTIAL
Bendix Commercial Vehicle Systems LLC
Elyria, OH 44036
PRODUCT SPECIFICATION - BW-283-PR
SPEC. BW-283-PR
73 SHEETS
SHEET NO. 64
7 Antilock application check list
This checklist is provided to assist in the verification of the ABS installation. It remains the
responsibility of the vehicle manufacturer to ensure system performance through the performance
of an EOL test.
Trailer ABS System Configuration
Is the correct Trailer ABS ECU(s) selected for the specific trailer application? (e.g.
4S/2M axle control for full trailer)
Yes No Don’t Know
Trailer ABS Assembly (ECU/Modulator Relay Valve)
Is the location of the assembly such that will not be subjected to direct wheel spray?
Yes No Don’t Know
Is the location of the assembly such that will not be subjected to temperatures less
than -40 °F or greater +185 °F?
Yes No Don’t Know
Is the exhaust port of the assembly facing in a downward direction?
Yes No Don’t Know
Is the exhaust port of the assembly unobstructed with significant free space below (>
1 inch)?
Yes No Don’t Know
Were all tube / brake hose fittings installed per the recommended manufacture's
specification?
Yes No Don’t Know
Are all unused delivery ports of the assembly plugged?
Yes No Don’t Know
For reservoir-mounted installations:
Is a heavy gauge steel nipple (Schedule 80) being used between the assembly's
supply port and the reservoir?
Yes No Don’t Know
Were following torque specifications used when installing pipe nipples?
Finger tight plus 1-1/2 turns with thread sealant
Finger tight plus 2 turns without thread sealant
Yes No Don’t Know
For frame-mounted installation:
Were the mounting fasteners torque's per the recommended manufacture's
specification?
Yes No Don’t Know
Is a minimum 5/8" tube fitting being used for the assembly's supply port?
Yes No Don’t Know
Remote Modulator Relay Valve
Is the location of the assembly such that will not be subjected to direct wheel spray?
Yes No Don’t Know
Is the location of the assembly such that will not be subjected to temperatures less
than -40 °F or greater +185 °F?
Yes No Don’t Know
Is the exhaust port of the assembly facing in a downward direction?
Yes No Don’t Know
Is the exhaust port of the assembly unobstructed with significant free space below (>
1 inch)?
Yes No Don’t Know
Were all tube / brake hose fittings installed per the recommended manufacture's
specification?
Yes No Don’t Know
Are all unused delivery ports of the assembly plugged?
Yes No Don’t Know
For reservoir-mounted installations:
Is a heavy gauge steel nipple (Schedule 80) being used between the assembly's
supply port and the reservoir?
Yes No Don’t Know
Were following torque specifications used when installing pipe nipples?
Finger tight plus 1-1/2 turns with thread sealant
Finger tight plus 2 turns without thread sealant
Yes No Don’t Know
For frame-mounted installation:
Were the mounting fasteners torque's per the recommended manufacture's
specification?
Yes No Don’t Know
Is a minimum 5/8" tube fitting being used for the assembly's supply port?
Yes No Don’t Know
Table 17: TABS6 OEM Application Check-List
DOCUMENTO CONTROLADO DE FORMATO ELECTRÓNICO: Antes de utilizarlo se requiere verificar el nivel de revision o la suficiencia.
CONTROLLED ELECTRONIC MEDIA DOCUMENT: Verification of revision level or adequacy is required prior to use.