Specifications
CONFIDENTIAL
Bendix Commercial Vehicle Systems LLC
Elyria, OH 44036
PRODUCT SPECIFICATION - BW-283-PR
SPEC. BW-283-PR
73 SHEETS
SHEET NO. 57
BCVS does not recommend using standard tie-wraps to secure wiring harnesses
directly to rubber airlines. This can cause premature wiring failure from
excessive expansion when air pressure is applied. Non-metallic hose clamps or
bow-tie tie-wraps are preferred.
Sensor
Sensor Mounting
Block
Secure To
Axle
Tie Wrap
To Service
Hose
Speed Sensor
Lead Wire
Secure to
Axle
Service Hose
Stress Loop
Figure 26: Wheel Speed Sensor Wire Routing
The use of grommets or other suitable protection whenever the cable must pass
through metallic frame members is required.
All sensor wiring must utilize twisted pair wire, with approximately one to two
twists per inch.
It is recommended that wires be routed straight out of a connector for a minimum
of three inches before the wire is allowed to bend.
If convoluted tubing is used, its inside diameter must match the size of the wire
bundle as closely as possible.
DOCUMENTO CONTROLADO DE FORMATO ELECTRÓNICO: Antes de utilizarlo se requiere verificar el nivel de revision o la suficiencia.
CONTROLLED ELECTRONIC MEDIA DOCUMENT: Verification of revision level or adequacy is required prior to use.