Technical data

6 720 611 447 GB (03.11)
4
Details of the appliance
1 Details of the appliance
1.1 EC Declaration of Conformity
This appliance is in accordance with the applicable
requirements of the Gas Appliance Directive, Boiler Effi-
ciency Directive, Electromagnetic Compatibility Direc-
tive and the Low Voltage Directive.
1.2 Standard package
Gas condensing combination boiler for central heat-
ing and domestic hot water
Control panel cover
Wall mounting frame
Room thermostat TR2
Fixings (screws etc.)
Set of documentation for appliance
Pre-plumbing manifold
Condensate drain pipe
Filling loop.
1.3 Description of appliance
Wall-mounted appliance, siting not dependent on
room size
Natural gas models are low-emission appliances
Multi function display
Bosch Heatronic control system with integrated text
display for service functions and faults
3-channel - digital timer for one heating circuit
Variable pump
Automatic ignition
Modulating control
Full safety systems incorporating Bosch Heatronic
with flame ionisation monitoring, solenoid valves and
temperature sensors
Concentric flue/air duct with testing point for
CO
2
/CO
Regulated speed fan
Pre-mix burner
Temperature control for central heating
Temperature sensor in domestic hot water
Safety temperature limiter in 24 V electrical circuit
Relief valve, pressure gauge, expansion vessel, Auto
air vent
Flue gas temperature limiter (105 °C)
Hot water priority circuit
Motorised 3-way valve
Plate-type heat exchange
Condensate Trap.
PIN CE-0085 BL0507
Category UK II
2H 3P
Appliance Type C
13
, C
33
Table 1