5. OPERATION OF CENTRAL HEATING
In order to turn on the central heating and adjust the temperature, turn the
control knob P1 to the desired setting between off and max 82°C.
When the control knob is turned the central heating water temperature will
flash and indicate the new temperature setting.
After a delay of 5 seconds the display will revert to a steady display of actual
central heating water temperature. This will disappear if there is no central
heating demand.
During a central heating demand the radiator symbol and the central heating
water temperature will be illuminated on the display.
If central heating is not required for any extended period turn the control
knob P1 fully anti-clockwise to the off position. In this position the “heating
off “ symbol will be displayed, the domestic hot water and frost protection
will still be active. This is also the “summer mode”.
6. OPERATION OF DOMESTIC HOT WATER
The domestic hot water temperature is adjustable between 30°C and 65°C
by the control knob P2.
When the control knob is turned the DHW water temperature will flash and
indicate the new temperature setting.
After a delay of 5 seconds the display will revert to a steady display of actual
DHW temperature. This will disappear if there is no DHW demand.
During a DHW demand, the tap symbol and the DHW temperature will be
illuminated on the display.
7. PRE-HEAT BUTTON
With the pre-heat button selected the boiler is maintained in a hot condition
to enable a fast response to any DHW demand. When selected, PRE-HEAT
will be illuminated on the display.
If required this can be selected for all year round use, but will be of
maximum benefit in the summer months, or when there is little or no
demand for central heating, in which case the boiler would become cold
without the pre-heat button selected.
The pre-heat function has a built-in intelligent function that will turn itself off
if there is no DHW demand for a 24 hour period. If previously selected, once
DHW water has been drawn off, the function will automatically re-enable.
8. RESET BUTTON
Should a fault occur this button can be pressed to reset the controls and
initiate a new start up sequence.
9. FLAME LOSS
Should the flame signal be lost 5 times in any 4 minute period then the
boiler will lockout and an error code will be displayed in the centre of the
display. Pressing the reset will enable the boiler to relight.
If the fault recurs, turn off the boiler and consult a CORGI registered
installer.
10. BOILER OVERHEATING
In the event of the boiler overheating the boiler will lockout and an error
code will be displayed in the centre of the display. Pressing the reset will
enable the boiler to relight.
If the fault recurs, turn off the boiler and consult a CORGI registered
installer.
82
˚
C
82
82
˚
C
65
˚
C
65
65
˚
C
ER:26
ER:03