Johnson & Starley Publication No. ZZ 1184-6 October 2008 Product Identification No: 87B 074 COMBI SERIES High Efficiency Combination Boilers USERS INSTRUCTIONS Natural Gas G20: Reno HE30C - GC No: 47-416-01 Reno HE37C - GC No: 47-416-02 Propane G31 Variants: Reno HE30CP - GC No: 47-416-04 Reno HE37CP - GC No: 47-416-03 The Johnson & Starley Reno range has an energy rating A on a scale of A to G. For more information see www.boilers.org.uk This is a certification mark. BS EN ISO 9001 : 2000 www.
COMBI SERIES High Efficiency Combination Boilers THE BENCHMARK SCHEME In order to comply with Building Regulations Part L (Part J in Scotland) the boiler MUST be fitted in accordance with the manufacturer’s instructions. Benchmark places responsibilities on both manufacturers and installers.
CONTENTS Benchmark Scheme 2 1. General Information 4 2. Symbols on the User Panel 4 3. Control Panel 5 4. Initial Lighting 5 5. Operation of Central Heating 6 6. Operation of Domestic Hot Water 6 7. Pre-Heat Button 6 8. Reset Button 6 9. Flame loss 6 10. Boiler Over Heating 6 11. Water System Pressure 7 12. Condensing Drain 7 13. Servicing & Maintenance 7 14. Escape of Gas 7 15. Cleaning the appliance 7 16. Error Codes 7 17. Analogue Time Control 8 18.
1. GENERAL INFORMATION Part of the installation and commissioning of this appliance is related to instructions for use by the heating engineer to the user where specific requirements may occur, see note below. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 2.
3. CONTROL PANEL The flip door at the bottom of the boiler is held in the closed position. To gain access to the control panel, take hold of the side of the panel at the corners and pull towards you, allowing the door to drop into the open position. To close the flip door, lift up the panel and push shut until it clicks into place.
5. OPERATION OF CENTRAL HEATING In order to turn on the central heating and adjust the temperature, turn the control knob P1 to the desired setting between off and max 82°C. When the control knob is turned the central heating water temperature will flash and indicate the new temperature setting. After a delay of 5 seconds the display will revert to a steady display of actual central heating water temperature. This will disappear if there is no central heating demand.
11. WATER SYSTEM PRESSURE The water system pressure is shown in the bottom right hand of the display. If the pressure drops below 1.0 bar it will begin to flash indicating the system needs to be topped up by a competent person. If the pressure continues to drop and reaches 0.6 bar, an error code will appear in the centre of the display and all heat demands will be blocked. This may indicate a leak and the system should be checked before being re-pressurised. 1.0 0 bar 0.9bar ER:37 12.
17. ANALOGUE TIME CONTROL (if fitted) SETTING THE TIME Indicator Arrow Rotate the dial clockwise, by hand, until the indicator arrow is pointing to the current time. I Note: The time is set in 24 hour format. SETTING THE CENTRAL HEATING ON AND OFF TIMES Select the on times by pushing the black tappets to the outside.
21. SELECTING AM - PM OR 24 HOUR CLOCK After pressing reset the display may show AM, numbered days will be flashing on and off. If the display does not show AM. It is in 24 hour mode, press and hold the h key and press the +/-1h key once. AM will appear in the display If display is in AM/PM mode and 24 hour time mode is desired, press and hold the h key, press the +/- key once 22. SETTING THE TIME If the h and m keys are held down longer than 2 seconds, the numbers will advance rapidly.
24. MANUAL GMT/BST TIME CHANGE OVER Each year, in the spring press +/- 1 hour to advance the time an hour. In the Autumn press +/- 1 hour to set back an hour 25. PROGRAMMING 24 HOUR OR 7 DAY SCHEDULE It may be helpful to write out the programme schedules before beginning. EXAMPLE:Event 1: On at 7.00am Monday through to Saturday Event 2: Off at 5.00pm Monday through to Friday Event 3: Off at 7.
28. CONTINUOUS OPERATION While in the run mode, press the permanently on. The key twice to turn the output to symbol appears in the display. To revert back to timed operation press the appears in the display. until the symbol 29. CHANGING AN EVENT Select the event to be changed with the Programme key. A new set of days may be selected with Day key just as in initial programming. Hours and minutes can be changed with the h and m keys Press the Programme key to store the new programme. 30.
Company Details Website Address Email www.johnsonandstarley.co.uk sales@johnsonandstarley.co.uk marketing@johnsonandstarley.co.uk Telephone Number Fax Number 01604 762881 (Main switchboard) 01604 767408 RENOXTRA HI-SPEC WARM AIR HEATERS HOME COMFORT SOLUTIONS ECONOMAIRE WARM AIR HEATERS Johnson & Starley are the leading UK & European manufacturers of a complete range of Domestic Warm Air Heaters.