Instruction manual

Benchmark Media Systems, Inc.
DAC1 - Manual - RevH-05-01-04 (2).doc Page 30 of 39 Ed. 1/4/2005 htt
p
THD+N vs. Level at 1 kHz – Balanced Outputs
Below –4 dBFS, distortion is lower than the noise floor of the converter. Above –3 dBFS, distortion reaches a
maximum value of only –107 dBFS.