User`s manual

14
MP-4200 TH Programmer’s Manual - Revision 1.0
GS F9h ‘ n
[Function] Getprinterinformation.
[Format] ASCII  GSF9h‘n
Hexadecimal 1DF927n
Decimal 2924939n
[Description]Retrieveprinterinformationaccordingtovaluesdescribedinthefollowingtable:
n Information Data type Return size
0,30h Productcode(“MP-4200TH”) ASCII string 10 bytes
1,31h Serial number ASCII string 20 bytes
2,32h Manufacturing date ASCII string 4 bytes
3,33h Firmware version ASCII string 3bytes
4,34h Reserved
5,35h Manufacturing timestamp (“dd/mm/yy
hh:mm:ss”format)
ASCII string 17bytes
6,36h Reserved
7,37h Reserved
8,38h Interface type (0 = None; 1 = Serial
DB-9;2=SerialDB-25;3=Ethernet,
-1=Unknown)
Integer 1 byte
GS F9h ( 0
[Function] Loaddefaultuserconfiguration.
[Format] ASCII  GSF9h(0
Hexadecimal 1DF92830
Decimal 292494048
[Description] Reloadallconfigurationsfromnon-volatilememoryanddipswitches.
GS F9h ) 0
[Function] Print user configuration.
[Format] ASCII  GSF9h)0
Hexadecimal 1DF92930
Decimal 292494148
[Description] Printonpaperthecurrentuserconfiguration.
GS F8h F
[Function] Printer reset.
[Format] ASCII  GSF8hF
Hexadecimal 1DF846
Decimal 2924870
[Description] Forceahardwareresetontheprinter.