Datasheet
PRODUCT SPECIFICATION
REVISION:
ECR/ECN NUMBER: DOCUMENT NUMBER
SHEET No.
1
EK2017-0***
PS-80397-001
6 of 11
DATE: CREATED / REVISED BY: CHECKED BY: APPROVED BY:
2017 / 05/ 22
Eric Bai
TEMPLATE FILENAME: PRODUCT_SPEC
REV 0.1,SHEET
SIZE
A4
20070830
14 Drop
76cm Height one carton 6-sydes random
dropping.
Appearance: No abnormality
Function : OK
5.4 ENVIRONMENTAL REQUIREMENTS
ITEM
TEST
DESCRIPTION
TEST CONDITION
REQUIREMENT
15 Thermal Shock
est Condition I
10 CYCLES –55℃ AND +85℃
No physical damage
&
10 milliohms MAX.
(change from initial)
16
Cyclic temperature
and Humidity
25 °C /80 %RH for 1hr. Upper-
Ramp
for 0.5hr
65 °C /50 %RH for 1 hr. Down-Ramp
for0.5hr,
Total 24 Cycles, 72hrs
Per EIA-364-31B
No physical damage
&
10 milliohms MAX.
(change from initial)
17 Temperature life
Mate connectors to expose to 105
±
2 ℃
for 120 hours.
Upon completion of the exposure period,
the test specimens shall be conditioned at
ambient room conditions for 1 to 2 hours,
after which the specified measurements
shall be performed.
Per EIA-364-17B, Test condition A
No physical damage
&
10 milliohms MAX.
(change from initial)