3.9.8 Durability
Comply with method EIA 364-09.
Test sample are subjected to fully mate and
unmate for 10000 cycles. The durability test shall
be done at a maximum rate of 200 cycles per
hour .
No physical damage to any
part of the connector.
3.9.9
Wrenching
Strength
The wrenching strength test shall be performed
using virgin parts. Perpendicular forces (Fp) are
applied to a plug when inserted at a distance
(L) of 15mm from the edge of the Connector.
These forces shall be applied in all four
direction.iie., left,right,up, and down).
No plug and Connector
damage shall occur when a force
of 0~50 N is applied;.
#:The plug may be damaged,
but only in such a way that the
Connector does not sustain
damage when a force of 50~75
N is applied ;
#:The plug shall be mated with
a different Connector after the
forces are applied to verity no
damage has occurred that
causes discontinuity or shorting.
3.9.10 Solder
ability
Comply with method EIA 364-52.
Soldered at a temperature 255 °C +/-5 °C for
an immersion duration of 5 s.
Solder shall cover a minimum
of 95% of the surface being
immersed.
3.9.11 Vibration
Comply with method EIA-364-28.
Vibration randomly from 20 to 500HZ at
condition VII, letter D(3.10G’s). Test duration for
each axis is 15 minute(total 45 minute).
No evidence of physical
damages.
Environmental Performance :
3.9.12
Temperature
Life
Comply with method EIA 364-17, Method A.
Temperature Life test temperature and
duration: 105º C without applied voltage for 120
hours.
105º C without applied voltage for 72 hours
when used as preconditioning in EIA 364-
1000.01.
After the test, the sample shall
pass the requirement of
3.9.1,3.9.2 specification.
3.9.13 Cycling
Temperature
and Humidity
Comply with method EIA 364-31.
Cycle the connector or socket between 25 °C
± 3 °C at
80 % ± 3% RH and 65 °C ± 3 °C at 50 % ± 3%
RH. Ramp times should be 0.5 hour and dwell
times should be 1.0 hour. Dwell times start
when the temperature and humidity have
stabilized within the specified
levels. Perform 24 such cycles.
After the test, the sample shall
pass the requirement of 3.9.1,
3.9.2 specification.
3.9.14 Thermal
Shock
Comply with method EIA 364-32,Test
Condition I.
10 cycles of mated connectors.
a) –55 for 30 minutes
b) +85 for 30 minutes
There shall be no evidence of
any physical damage.
3.9.15 Thermal
disturbance
Cycle the connector or socket between 15 °C
± 3 °C and 85 °C ±3 °C, as measured on the
part.Ramps should be a minimum of 2°C per
minute, and dwell times should insure that the
contacts reach the temperature extremes (a
minimum of 5 minutes). Humidity is not
controlled. Perform 10 such cycles.
After the test, the sample shall
pass the requirement of 3.9.1,
3.9.2 specification.
3.9.16 Thermal
Cycling
Cycle the connector or socket between 15 °C
± 3 °C. and 85 °C ±3 °C, as measured on the
part.Ramps should be a minimum of 2 °C per
minute, and dwell times should insure that the
contacts reach the temperature extremes (a
After the test, the sample shall
pass the requirement of 3.9.1,
3.9.2 specification.